3.4 Chimneys and flue pipes

•  A chimney can be linked to the fireplace and flue approved 

for solid fuel-fired fireplaces with a flue gas temperature as 

specified in 

«2.0 Technical data»

•  The cross-section of the chimney must be at least equal to 

the cross-section of the flue. Please use 

«2.0 Technical data» 

to calculate the correct cross-section of the chimney. 

•  Several solid fuel-fired fireplaces can be connected to the 

same chimney if the cross-section of the chimney is adequate.

• 

Connection to the chimney must be carried out in accordance 

with the installation instructions from the supplier of the 

chimney. 

•  Before making a hole in the chimney the fireplace should be 

test-mounted in order to correctly mark the position of the 

fireplace and the hole in the chimney.  See 

fig. 1

 for minimum 

dimensions. 

•  Ensure that the flue pipe is inclined all the way up to the 

chimney.

•  Use a flue pipe bend with a sweeping hatch that allows it 

to be swept.

Be aware of the fact that connections must have a certain 

flexibility in order to prevent movement in the installation 

leading to cracks.

 N.B. A correct and sealed connection is very 

important for the proper functioning of the product.

The chimney draught, see «2.0 Technical data». If the draught is 

too strong you can install and operate a flue damper to control 

the draught.

3.5 Assembly prior to installation

N.B. Check that the fireplace is free of any damage prior to 

commencing installation. 

The product is heavy! Make sure you have assistance when 

erecting and installing the fireplace.

The product is delivered in a single packing case where the legs, 

heat shield and door knob must be assembled.

1.  Remove the cooking plate and all the separate parts inside 

the stove. 

(Fig. 2)

2.  Place the cardboard packaging on the floor and lay the stove 

carefully down on its side. Fasten the 4 legs with screws and 

washers. 

(Fig. 3)

3.  If it is necessary to protect the walls, use the enclosed heat 

shield. Use the bracket to connect the side heat shield to the 

base heat shield. Fasten the bracket in the center of the base 

plate with a screw.

4.  The flue outlet 

(fig. 4)

 and the blanking plate exchange 

positions if the smoke outlet on top of the stove is preferred. 

The two screws on the flue outlet may be somewhat 

difficult to release. Hold on to the nut on the inside with a 

small wrench of the flue outlet to release the screws on the 

outside. Ensure all possible unused flue outlets are suitably 

blanked off.

5.  Place the flue pipe’s end outside the product’s smoke outlet. 

Fill any gaps between the flue pipe and smoke outlet with 

suitable gasket.

6. Connect 

the 

knob 

(fig. 2A)

 to the door latch with the screw 

and nut provided.

3.6 Control of functions (fig. 6)

When the product is set up, always check the control functions. 

These shall move easily and function satisfactorily.

Jøtul Jøtul F 

602 

N is equipped with the following controls:

Air vent control, Fig. 5A:

Left position:  

closed

Right position:  open

3.7 Ash removal

•  Transfer the ashes through the door with a shovel or similar 

tool. 

•  Leave a little ash in the bottom of the combustion chamber 

as a protective insulating layer. Ashes should be placed in a 

metal container with a tight fitting lid.

For the rest, see description of how to handle ash in the Manual 

on general use and maintenance in Point

«6.1 Fire preventive 

measures».

4.0 Service

Warning!

 Any unauthorised change to the product is illegal! 

Only use original spare parts!

4.1 Changing the burn plates (Fig. 

7

)

•  Remove the old burn plates by lifting them off the boss.

•  Brush clean the side plates in the oven before installing the 

new burn plates.

•  Lift the baffle plate by the front edge.

•  Start with the left burn plate.

•  Hang the burn plate on the boss of the side plate as shown 

in 

fig. 

7

A

. This way the highest part of the burn plate is 

supported by the ridge 

(fig. 

7

B)

 at the upper edge.

Note: Older models of Jøtul F 602 N have an additional two 

bosses on each side plate. The burn plates fit on the boss furthest 

to the front.

4.2 Changing the baffle plate

•  Remove the old baffle plate by lifting it slightly up and then 

edging it down and out.

•  To reinstall, make sure the baffle plate rests securely on the 

ridge in the rear 

(fig. 

7

C)

 and on the bosses in front.

Important note: If the baffle plate is positioned incorrectly, the 

flue gas will go straight into the flue pipe. This will result in too 

high flue gas temperatures, which may damage the rear plate, 

and it will make heating uneconomical.

5.0 Optional Equipment 

Glass door, cat.no. 320073.