HEIDENHAIN ND 1400 Quick Start: Setup
Setup: HEIDENHAIN ND 1400 Quick Start

Setup
Initial power up
Software setup
3. Enter the Supervisor Password
• Press the POWER SWITCH to power
The operating parameters of the
• Touch the SUPERVISOR setup menu
the ND 1400. The startup screen is
ND 1400 must be configured prior
item and then touch the PASSWORD
displayed.
to using it for the first time, and any
field.
time part measurement, reporting or
• Enter the supervisor password.
communication requirements change.
Settings will be retained until:
• The data-backup battery is changed
• The data and settings are cleared
• Software upgrades are performed
Caution
Setup parameters control the operation
of the ND 1400 and are password-
• Press the FINISH key to display the
protected. Only qualified personnel
current axis positions on the DRO
should be given password access to
4. Calibrate the touch screen
screen.
setup screens.
The touch screen should be calibrated
to respond correctly to each operator’s
1. Display the setup menu
finger tip size and pressure.
• Touch the QUESTION icon
• Touch the MISCELLANEOUS setup
once, and then touch the
menu item and then touch the CAL
SETUP button twice to
button.
display the SETUP MENU.
• Follow the instructions shown on the
LCD screen.
5. Select a probe
• Touch the PROBE setup menu item
and then touch the PROBE HOLDER
field to select the desired probe type.
• Prepare for probe qualification by
touching the QUALIFICATION
DIAMETER field and entering the
qualification sphere diameter in the
correct unit of measure.
6. Select the point entry type
• Touch menu items to select them.
Backward or forward annotation can be
Scroll the setup menu using the
used to collect data points. Backward
ARROW buttons.
annotation allows the user to probe
any number of data points to measure
2. Select the language
a feature. Forward annotation limits
Touch the LANGUAGES setup menu
the number of points to a required
item and then touch the desired
minimum.
language.
• Touch the MEASURE setup
menu item and then touch the
ANNOTATION field to select
Note:
BACKWARD or FORWARD
When the language is changed, power
annotation.
to the ND 1400 must be cycled off and
then back on.
2
Оглавление
- ND 1400 QUADRA-CHEK
- ND 1400 QUADRA-CHEK English Setup
- Setup
- Operation
- ND 1400 QUADRA-CHEK Deutsch Setup
- Setup
- Bedienung
- ND 1400 QUADRA-CHEK Français Paramétrage
- Paramétrage
- Fonctionnement
- ND 1400 QUADRA-CHEK Italiano Configurazione
- Configurazione
- Funzionamento
- ND 1400 QUADRA-CHEK Español Ajustes
- Ajustes
- Operación
- ND 1400 QUADRA-CHEK Svenska Inställning
- Inställning
- Handhavande
- ND 1400 QUADRA-CHEK Nederlands Instellen
- Instellen
- Bediening
- ND 1400 QUADRA-CHEK Česky Nastavení
- Nastavení
-
- ND 1400 QUADRA-CHEK Português Configurar
- Configurar
- Funcionamento
- ND 1400 QUADRA-CHEK Język polski Setup
- Setup
-
- ND 1400 QUADRA-CHEK Русский
-
-
- ND 1400 QUADRA-CHEK Türkçe Ayarlar
- Ayar
-
- ND 1400 QUADRA-CHEK Nihongo
-
-
- ND 1400 QUADRA-CHEK
-
-
- ND 1400 QUADRA-CHEK
-
-
- ND 1400 QUADRA-CHEK