Maxwell MW-3552 VT: ENGLISH
ENGLISH: Maxwell MW-3552 VT
ENGLISH
Ultrasonic air humidifier MW-3552
Description
1. Nozzle for steam output
2. Water reservoir
3. Water tank lid
4. Operating chamber with the sprayer
5. Steam switch/control
6. Operating/No water indicator
7. Brush for cleaning of the sprayer
SAFETY MEASURES
Before using the device, please, attentively read these instructions and keep them for the whole
operation period.
• Before switching on make sure that the voltage of the electric network corresponds to the
operating voltage of the unit.
• Place the unit on the flat, moisture-resistant surface. Distance from the walls should be not less
than 15 cm.
• Do not direct the nozzle of the unit at the wooden furniture, electrical appliances, books and
objects, which can be damaged by moisture.
• Do not place the humidifier in the places subjected to direct sun light, high temperatures, near
computers or other sensitive electronic appliances.
• Do not leave the unit unattended in closed rooms otherwise condensation can appear on the
furniture and the walls, that is why we recommend keeping the door of the room, where the
humidifier is used, half-opened.
• It is forbidden to use the device out of doors.
• Use only the removable parts which are supplied with the unit.
• Do not allow children to use the kettle as a toy.
• This unit is not intended for usage by children or disabled persons. This unit is not intended for
usage by children or disabled persons unless they are given all the necessary instructions on
safety measures and information about danger, which can be caused by improper usage of the
unit.
• Do not switch on the unit without water. Disconnect the unit from the power supply when the
water tank becomes empty.
• Do not use soda water or any perfume additives.
• Always unplug the unit and before taking the water tank out of the unit.
• Do not block steam outlets and provide that foreign objects do not get inside them.
• Do not immerse the unit, the power plug or the power cord into water or other liquids.
• Do not move or tilt the unit during its operation.
• Always unplug the unit and pour out water from the water tank during cleaning the unit, if you do
not use it.
• Unplug the unit before moving it to another place.
• Do not touch the power plug with wet hands.
• Before using the unit, closely examine the power cord and make sure that it is not damaged. Do
not use the unit, if its power cord is damaged.
• Do not dismantle the unit yourself, if any malfunction is detected, apply to the nearest authorized
service center.
• Regularly clean the unit; do not allow cracks to appear on the sprayer.
7
7
3552.indd 73552.indd 7 09.09.2011 15:00:4409.09.2011 15:00:44
ENGLISH
FOR HOUSEHOLD USAGE ONLY
BEFORE USING THE UNIT FOR THE FIRST TIME
• Unpack the unit and remove the packing materials. Examine the unit for damages. Do not switch
on the unit if there are any damages in it.
Note:
− if the unit was subjected to negative temperatures, before switching it on for the first time, keep
it at room temperature for 30 minutes.
− use the unit at +5 - +40°С temperature, and relative humidity less than 80%.
− water temperature should not exceed +40°С.
• Before switching on the unit, make sure that the voltage of the electric network corresponds to the
operating voltage of the unit.
Using the ultrasonic air humidifier
1. Remove the nozzle (1) from the water tank (2).
2. Remove the water tank (2) from unit.
3. Turn over the tank (2); unscrew the lid (3), by turning it anti clockwise.
4. Fill the water tank (2) with necessary quantity of water and screw the lid (3), by turning it clock-
wise.
5. Set the filled tank (2) on the body of the unit.
6. Insert the plug into the socket.
7. Switch on the unit, by turning the switch (5) clockwise, the indicator (6) will light green.
8. Regulate steam intensity by turning the regulator (5).
9. If there is no water in the water tank (2) the indicator will light red
10. Use the switch (5) to switch off the unit and then unplug it. Fill the tank (2) with water and set
the filled tank on the body of the unit.
11. Upon termination of work turn the unit off by turning the regulator (5) counter-clockwise up to
full stop, the indicator of operation (6) will go out.
Clean and care
Warning: Always switch off and unplug the unit before cleaning.
Hard water causes appearance of scale on the “sprayer”(4) and in the operating chamber; it leads to
improper operation of the unit and appearance of white deposit on the interior objects. To avoid it:
− use boiled water or water, which stood for some time, water, purified by filter or distilled water;
− clean the operating chamber (4) weekly;
− change water in the water tank (2) more often.
Weekly care
− Once a week carefully wash the water tank (2) and the operating chamber (4) with a neutral
washing liquid solution. After it rinse them thoroughly with water.
− Add 5-10 drops of the cleaning agent on the “sprayer” (4); wait about 2-5 minutes. Use the
brush (7) to remove the deposit from the surface of the “sprayer” (4).
Note:
• As a cleaning agent for the “sprayer” you can use substances for scale removal in kettles.
• Do not immerse the unit into water or other liquids.
88
3552.indd 83552.indd 8 09.09.2011 15:00:4409.09.2011 15:00:44
ENGLISH
Storage
− Before taking the unit away for storage, pour out water from the water tank (2) and from the
operating chamber (4), wipe the operating chamber (4) dry.
− Do not store the unit with water in the water tank or if water remains in the operating chamber.
− Keep the humidifier in a dry cool place out of reach of children.
TROUBLESHOOTING
Failure Possible causes Troubleshooting
Plug the unit
The operating indicator
No voltage, no power
is not lighting, no steam
supply
Plug in another, properly operating
formation
device, to make sure that the socket is
in good operating condition.
The operating indicator
There is no water in the
Fill the water tank with water.
is lighting red, no steam
water tank.
formation
“Steam” has an
New device – it is
Unscrew the lid of the water tank, pour
unpleasant smell
normal
out water and leave the unit for 12
hours in a cool dark place
Unplug the unit, remove the water
Polluted or stagnant
tank, pour out water, wash the water
water
tank, and fill the water tank with boiled
or distilled water.
Small intensity of “steam”
Polluted “sprayer” Unplug the unit and clean the sprayer.
output
The unit is placed on
Unplug the unit and even the body
Abnormal noise during
the uneven or unstable
of the unit or move the humidifier to
operation of the unit
surface
another place.
NOTE:
Non-observance of rules for cleaning the unit from mineral deposits caused by hard water may
affect the overall performance of the unit. In this case clean the unit. If used water is too hard, use
household filters to purify water or mix tapping water with distilled water in proportion 1:1.
DELIVERY SET
Instruction manual – 1 pc.
Removable nozzle - 1 pc.
Removable water tank – 1 pc.
Removable water tank lid – 1 pc.
Instruction manual – 1 pc.
Technical specifications
Power supply: 220-240 V ~ 50 Hz
Power consumption: 30 W
9
3552.indd 93552.indd 9 09.09.2011 15:00:4409.09.2011 15:00:44
ENGLISH
Water tank 1.4 L
Water flow: 250 ml/hour
Humidifying area up to 15 m2
The manufacturer preserves the right to change the design and the specifications of the unit
without a preliminary notification.
Service life of the unit is 3 years
GUARANTEE
Details regarding guarantee conditions can be obtained from the dealer from whom the appliance
was purchased. The bill of sale or receipt must be produced when making any claim under the terms
of this guarantee.
This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/
EEC and to the Law Voltage Regulation (73/23 EEC)
10
3552.indd 103552.indd 10 09.09.2011 15:00:4409.09.2011 15:00:44