Thermor Variations de Silhouette: USING THE PANEL HEATER
USING THE PANEL HEATER: Thermor Variations de Silhouette

Table of commands the panel heater can receive on its pilot wire. To be measured between the pilot wire and the neutral.
onnoitanretlA
onnoitanretlA
sdnammoC
etelpmoC
-flahevitageN
-flahevitisoP
tnerrucoN
)''75'4(tnerruc
)''35'4(tnerruc
devieceR
V032noitanretla
V511-noitanretla
V511+noitanretla
)''3(V032esahp
)''7(V032esahp
epocsollicsO
lartueN/féR
edoM
trofmoCC°1-trofmoCC°2-trofmoCocEezeerf-itnApotStuCrewoP
deniatbo
2-4) Lock the appliance on the hook-on bracket
66
66
6
USING THE PANEL HEATER
1) Description of the control unit :
99
99
9
➔ Mode switch knob.
➔ COMFORT temperature set value adjustment knob.
➔ ECO temperature set value adjustment knob.
V1 ➔ Heating light.
V2 ➔ COMFORT mode light.
V3 ➔ ECO light.
2) Fixing the comfort temperature :
The comfort temperature that you would like while the room is occupied.
a) Set the cursor to
, the heating light V2 comes on.
b) Set the control knob to 5, the heating light V1 comes on, if the room temperature is below the required temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
3) Fixing the Eco temperature :
This involves a reduction in degrees compared to the Comfort temperature. We recommend that you use this mode for
periods of absence of more than 2 hours or overnight.Warning: This reduction applies to the Comfort temperature so it is
important to set the Comfort temperature first, before setting the Eco reduction.
a) Set cursor to
, indicator light V3 lights up.
b) Set the knob to –3.5°, the heating indicator light V1 comes on if the ambient temperature is less than the desired Eco
temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
NB: The measurement is set to –3.5°C in our laboratories. It is possible that the setting for the reduction is not precisely
–3.5°C, depending on your installation’s particular characteristics. In this case, adapt the setting to obtain the desired
reduction.
4) Frost-Free mode :
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for a
prolonged period (i.e. more than 24 hours).
a) Set the cursor to
.
5) The heating indicator : V1
This light indicates periods during which the element is heating. It flashes when the temperature is stable, and it goes off
if the temperature is too high.
6) Switching off the device :
To set the device to the Off position, move the cursor to .
7) Locking the controls :
It is possible to lock or limit the range of use of thumb-wheels and and lock selector switch cursor to prevent the
inadvertent manipulation of the device (by children, etc).
a) Detach the device from its wall bracket.
b) On the back of the thermostat box, detach pins P from their supports.
c) Choose position B to lock the thumb-wheels or position L to limit the range of use of the thumb-wheels.
Choose one of the positions M to lock the person in the desired mode.
080214_CEETvariation_ang.PMD 14/12/2007, 08:022
Оглавление
- INSTALLATION DE L’APPAREIL
- UTILISATION DE L’APPAREIL
- CONSEILS D’UTILISATION
- ENTRETIEN
- INSTALLATIE VAN HET APPARAAT
- GEBRUIK VAN HET TOESTEL
- GEBRUIKSTIPS
- BIJ PROBLEMEN
- INSTALLATION DES GERÄTS
- BEDIENUNGSANLEITUNG FÜR IHR GERÄT
- GEBRAUCHSEMPFEHLUNGEN
- IM FALL VON PROBLEMEN
- INSTALACJA URZĄDZENIAINSTALACJA URZĄDZENIA
- UŻYTKOWANIE OGRZEWACZA
- ZALECENIA UŻYTKOWANIAZALECENIA UŻYTKOWANIA
- W PRZYPADKU WYSTĄPIENIA PROBLEMÓWW PRZYPADKU WYSTĄPIENIA PROBLEMÓW
- УСТАНОВКА ПРИБОРАУСТАНОВКА ПРИБОРА
- КАК ПОЛЬЗОВАТЬСЯ ВАШИМ АППАРАТОМКАК ПОЛЬЗОВАТЬСЯ ВАШИМ АППАРАТОМ
- РЕКОМЕНДАЦИИ ДЛЯ ПОЛЬЗЫРЕКОМЕНДАЦИИ ДЛЯ ПОЛЬЗЫ
- INSTALLATION OF THE PANEL HEATER
- USING THE PANEL HEATER
- RECOMMANDATIONS FOR USE
- TROUBLE-SHOOTING
- 4, 4bis