Dell PowerEdge VRTX: Jumpers And Connectors

Jumpers And Connectors: Dell PowerEdge VRTX

6

Jumpers And Connectors

System Board Jumper Settings

CAUTION: Many repairs may only be done by a certified service technician. You should only perform

troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or

telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your

warranty. Read and follow the safety instructions that came with the product.

For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password.

Table 4. System Board Jumper Settings

Jumper Setting Description

PWRD_EN

(default)

The password feature is enabled.

The password feature is disabled.

NVRAM_CLR

(default)

The configuration settings are retained at system boot.

The configuration settings are cleared at the next system boot.

(If the configuration settings become corrupted to the point

where the system does not boot, install the jumper and boot

the system. Remove the jumper before restoring the

configuration information.)

65

System Board Connectors

Figure 25. System Board Connectors

Table 5. System Board Connectors

Item Connector Description

1 BATTERY Connector for the 3.0 V coin cell battery

2 CPU2 Processor socket 2

3 B3, B7, B11, B4, B8, B12 Memory module sockets (for processor 2)

4 A1, A5, A9, A2, A6, A10 Memory module sockets (for processor 1)

5 CPU1 Processor socket 1

6 MANAGEMENT RISER Management riser card connector

7 MEZZ1_FAB_C PCIe Mezzanine card connector for Fabric C

8 MEZZ2_FAB_B PCIe Mezzanine card connector for Fabric B

9 vFLASH SD vFlash card connector

10 NETWORK DAUGHTER

Network daughter card connector

CARD

11 A3, A7, A11, A4, A8, A12 Memory module sockets (for processor 1)

12 B1, B5, B9, B2, B6, B10 Memory module sockets (for processor 2)

13 PWRD_EN, NVRAM_CLR

System configuration jumpers

NOTE: Access requires removal of system board.

14 HD_BP Hard-drive/SSD backplane connector

66

Item Connector Description

15 STORAGE PCIe extender card/storage controller card connector

16 USB2 USB connector

17 USB1 USB connector

Disabling A Forgotten Password

The server modules software security features include a system password and a setup password. The password jumper

enables these password features or disables them, and clears any password(s) currently in use.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform

troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or

telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your

warranty. Read and follow the safety instructions that came with the product.

1. Remove the server module from the enclosure.

2. Open the server module.

3. Remove the system board to gain access to the jumpers.

4. Relocate the jumper plug to disable the password feature.

5. Reinstall the system board.

6. Close the server module.

7. Install the server module in the enclosure.

When the server module is on, the power-on indicator is solid green. Allow the server module to finish booting.

The existing passwords are not disabled (erased) until the system boots with the password removed. However,

before you assign a new system and/or setup password, you must reinstall the password jumper.

NOTE: If you assign a new system and/or setup password with the jumper removed, the system disables the

new password(s) the next time it boots.

8. Remove the server module from the enclosure.

9. Open the server module.

10. Remove the system board to gain access to the jumpers.

11. Relocate the jumper plug to enable the password feature.

12. Reinstall the system board.

13. Close the server module.

14. Install the server module in the enclosure.

15. Assign a new system and/or setup password.

67

68