Variolink® Esthetic is a colour-stable, adhesive luting system for the permanent
cementation of ceramic and composite resin restorations. Variolink Esthetic
is offered in a purely light-curing (Variolink Esthetic LC) and a dual-curing
version (Variolink Esthetic DC).
The special filler composition gives Variolink Esthetic a very high radiopacity.
Shades
Variolink Esthetic is available in the following five shade gradations:
Shade Effect
Light + Translucency approx. 5%
Lighter /
(opaque)
more whitish
Light Translucency approx. 10%
Neutral Translucency approx. 17% None
Warm Translucency approx. 12%
Warm + Translucency approx. 8.5%
Darker /
(opaque)
more yellowish
The gradation of Variolink Esthetic shades is based on the effect that a luting
composite exerts on the brightness value of the final restoration. Variolink
Esthetic Neutral does not affect the brightness value. At the same time, it
demonstrates the highest translucency and is thus neutral in shade. Light
and Light + make the restorations lighter, while Warm and Warm + create a
darker overall shade impression. In order to evaluate the overall effect of the
restoration in conjunction with the various Variolink Esthetic shades prior to
permanent cementation, we recommend using the Variolink Esthetic try-in
pastes.
Composition
The monomer matrix of Variolink Esthetic is composed of urethane
dimethacrylate and further methacrylate monomers. The inorganic fillers
are ytterbium trifluoride and spheroid mixed oxide. Initiators, stabilizers and
pigments are additional ingredients.
The particle size is 0.04-0.2 μm. The mean particle size is 0.1 µm.
The total volume of inorganic fillers is approx. 38%.
Indication
– Permanent adhesive luting of glass-ceramic, lithium disilicate glass-
ceramic and composite restorations (inlays, onlays and veneers)
– Only use Variolink Esthetic LC for restorations with a low thickness of
<2mm that have sufficient translucency (e.g. restorations made of
IPS e.max® HT).
– The following overview provides recommendations for the selection of
the suitable Variolink Esthetic LC shade:
do t’i gjeni në
utilizare, vă rugăm să utilizați
link-ul de mai jos
з інструкціями із
застосування, будь ласка,
відвідайте сайт
aadressil
skatiet vietnē
rasite apsilankę
SQ Udhëzimet e përdorimit
RO Pentru instrucțiuni de
UK Для ознайомлення
ET Kasutusjuhend asub
LV Lietošanas instrukcijas
LT Naudojimo instrukcijas
Esthetic LC
®
obiščite
pronaći na adresi:
na internetové stránce
nájdete na
utasításokért keresse fel a
можете наћи на интернет
адреси
се наоѓа на веб страната
SL Za navodila za uporabo
HR Upute za upotrebu možete
CS Návod k použití naleznete
SK Návod na použitie
HU Kérjük, használati
SR Упутство за употребу
MK Упатството за употреба
hammaskiinnitysmateriaali
festemateriale
bevestigingsmateriaal op basis van
kunsthars
ρητινώδης κονία
yapıştırma materyali
Bruksanvisning
DA Brugsanvisning
– Lyshærdende permanent plastcement
FI Käyttöohjeet
– Valokovetteinen hartsipohjainen
NO
– Lysherdende, harpiksbasert dentalt
NL Productinformatie
– Tandheelkundig, lichtuithardend
EL Oδηγίες Xρήσεως
– Φωτοπολυμεριζόμενη οδοντιατρική
TR Kullanma Talimatı
– Işıkla sertleşen rezin esaslı dental
Esthetic LC Variolink
®
material
Befestigungscomposite
photopolymérisable à usage dentaire
fotoindurente
fotopolimerizable basado en resina
de resina fotoativada
Variolink
EN Instructions for Use
– Light-curing resin-based dental luting
DE Gebrauchsinformation
– Lichthärtendes zahnärztliches
FR Mode d’emploi
– Composite de collage
IT Istruzioni d’uso
– Cemento composito dentale
ES Instrucciones de uso
– Material dental de cementado
PT Instruções de Uso
– Material de cimentação dental à base

Indications
Shade Effect Veneers Inlays / Onlays
Light + considerably lightens
✔
--*
Light slightly lightens
✔ ✔
Neutral no shade effect
✔ ✔
Warm slightly darkens/
✔ ✔
more yellowish
Warm + considerably darkens/
✔
--*
more yellowish
* The use of the shades Light+ and Warm+ may lead to visible restoration margins when
cementing inlays/onlays.
Contraindication
The application of Variolink Esthetic is contraindicated
– if a dry working field cannot be established or the stipulated working
procedures cannot be applied;
– if a patient is known to be allergic to any of the ingredients of Variolink
Esthetic.
Side effects
Systemic side effects are not known to date. In individual cases, allergic
reactions to individual components have been reported.
Interactions
Phenolic substances (e.g. eugenol, wintergreen oil) inhibit polymerization.
Consequently, the application of products containing these components, e.g.
mouth rinses and temporary cements, must be avoided.
Disinfectants with an oxidative effect (e.g. hydrogen peroxide) may interact
with the initiator system, which in turn may impair the curing process.
Therefore, do not disinfect the preparation and the syringe using oxidative
agents. Disinfection may be carried out, for instance, by wiping with medical
alcohol.
Alkaline jet mediums applied on dentin (e.g. Airflow) may compromise the
effect of self-etching adhesives.
Application
For more detailed information also refer to the Instructions for Use of the
products used in conjunction with Variolink Esthetic.
1 Removal of temporary restoration and cleaning of the cavity
Remove possible residue of the temporary luting composite from the
cavity or the preparation with a polishing brush and an oil- and fluoride-
free cleaning paste (e.g. Proxyt® fluoride-free prophy paste). Rinse with
water spray.
Subsequently, dry with oil- and moisture-free air. Avoid overdrying.
Note:
Cleaning with alcohol can lead to dehydration of dentin.
2 Try-in of the restoration and isolation
Seat the restoration using the desired Variolink Esthetic try-in paste and
check the shade, fit and occlusion of the restoration.
Care should be taken when checking the occlusion of fragile and brittle
ceramic objects before they are permanently cemented, as there is a risk
of fracture.
If necessary, make adjustments with fine diamonds at medium speed
and with slight pressure and adequate water cooling. Polish ground
surfaces.
When an adhesive luting protocol with composites is used, safe isolation
of the operating field – preferably with a rubber dam, e.g. OptraDam®
Plus, or alternatively with cotton rolls and a saliva ejector – is required.
If the dental hard tissue is contaminated with saliva or blood during
try-in, it needs to be cleaned again as described in section 1.
3 Pre-treatment of the restoration
3.1 If a restoration which has been pre-treated in the dental laboratory
is contaminated with saliva or blood during try-in, the contaminated
bonding surface of the restoration needs to be cleaned as follows:
– Following try-in, thoroughly rinse the restoration with water spray
and dry with oil-free air.
– Shake Ivoclean before use and completely coat the bonding surface of
the restoration with the product using a microbrush or bush.
– Leave Ivoclean to react for 20 s, then thoroughly rinse with water
spray and dry with oil-free air.
– Subsequently, prime the bonding surfaces with a bonding agent that
is appropriate for the respective restorative material (e.g. Monobond®
Plus). Make sure to observe the Instructions for Use of the bonding
agent applied.
3.2 Restorations that have not been pre-treated by the dental laboratory
should be rinsed with water spray and dried after the try-in procedure.
3.2.1 Subsequently, condition the bonding surfaces of the restoration as
follows:
a) Glass-ceramic restorations (e.g. IPS Empress®)
®
– Etch with 5% hydrofluoric acid (e.g. IPS
Ceramic etching gel) for
60 s or according to the instructions of the manufacturer of the
restorative material.
– Thoroughly rinse with water spray and dry with oil-free air.
b) Lithium disilicate glass-ceramic restorations (e.g. IPS e.max Press,
IPS e.max CAD)
– Etch with 5% hydrofluoric acid (e.g. IPS Ceramic etching gel) for
20 s or according to the instructions of the manufacturer of the
restorative material.
– Thoroughly rinse with water spray and dry with oil-free air.
c) Composite or fibre-reinforced composite restorations
– Blast the internal surface of the restoration (according to the
instructions of the manufacturer of the restorative material).
– If necessary, clean the restoration in an ultrasonic unit for about
one minute.
– Thoroughly rinse with water spray and dry with oil-free air.
3.2.2 Apply Monobond Plus with a brush or a microbrush to the pre-treated
surfaces, let it react for 60 s and then disperse it with a strong stream of air.
4 Pre-treatment of the preparation and application of the adhesive
(e.g. Adhese® Universal)
Please observe the Instructions for Use of the adhesive used.

4.1 Conditioning with phosphoric acid gel (optional)
The bond to enamel can be improved by selectively etching the enamel
or by applying the ”etch & rinse“ technique. Unprepared enamel surfaces
must be conditioned with phosphoric acid (e.g. Total Etch). Please
observe the Instructions for Use for the phosphoric acid gel.
a) Selective enamel etching
Apply phosphoric acid gel (e.g. Total Etch) onto the enamel and allow
it to react for 15-30 s. Then rinse thoroughly with a vigorous stream
of water for at least 5 s and dry with compressed air until the etched
enamel surfaces appear chalky white.
b) Etch & rinse technique
Apply phosphoric acid gel (e.g. Total Etch) onto the prepared enamel
first, and then to the dentin. The etchant should be left to react on
the enamel for 15-30 s and on the dentin for 10-15 s. Then rinse
thoroughly with a vigorous stream of water for at least 5 s and dry
with compressed air until the etched enamel surfaces appear chalky
white.
4.2 Application of Adhese Universal
– Starting with the enamel, thoroughly coat the tooth surfaces to be
treated with Adhese Universal.
– The adhesive must be scrubbed into the tooth surface for at least 20 s.
This time must not be shortened. Applying the adhesive on the tooth
surface without scrubbing is inadequate.
– Disperse Adhese Universal with oil- and moisture-free compressed air
until a glossy, immobile film layer results.
– Light-cure Adhese Universal for 10 s using a light intensity of
≥500 mW/cm² (e.g. Bluephase® Style).
5 Seating of the restoration
– Variolink Esthetic LC is sensitive to any blue light (operatory light,
ambient light). Therefore, Variolink Esthetic LC should not be
dispensed until right before use. Exposure to intensive light should be
avoided during application.
– Apply Variolink Esthetic LC with the application tip or a brush/
spatula directly to the internal surface of the restoration. The
direct application of Variolink Esthetic to the preparation or cavity
pretreated with adhesive is contraindicated.
– Seat the restoration and fix/hold it in place during excess removal.
– Remove all excess luting material.
a) Wiping technique
Remove excess material immediately with a micro-brush/brush/
foam pellet/dental floss or scaler. Make sure to remove excess
material in time, especially in areas that are difficult to reach
(proximal areas, gingival margins).
b) Circular technique suitable for veneers / inlays / onlays – Light-
curing of excess and subsequent removal
Light-cure excess material with a polymerization light (light intensity
≥ 500mW/cm²; e.g. Bluephase Style) for 2 s at a distance of
10-15 mm by running the light probe along the entire cement line.
www.ivoclarvivadent.com/ifu
употреба, моля, посетете
BG За инструкциите за
композитный цемент светового
отверждения
RU Инструкция по применению
– Стоматологический фиксирующий
PL Instrukcja stosowania
– Cement światłoutwardzalny
Manufacturer
Ivoclar Vivadent AG
FL-9494 Schaan/Liechtenstein
kompositcement
SV Bruksanvisning
– Ljushärdande dentalt
Rx ONLY
Date information prepared:
2014-07-09/Rev. 1
666333/WW