Ardo CN60inox: ENGLISH GENERAL SAFETY PRECAUTION INSTALLATION INSTRUCTIONS

ENGLISH GENERAL SAFETY PRECAUTION INSTALLATION INSTRUCTIONS: Ardo CN60inox

Table of contents

GB

ENGLISH

• Electric Connection

GENERAL

The appliance has been manufactured as a class II,

therefore no earth cable is necessary.

Carefully read the following important information regarding

The connection to the mains is carried out as follows:

installation safety and maintenance. Keep this information

BROWN = L line

booklet accessible for further consultations.

BLUE = N neutral

The appliance has been designed for use in the ducting

If not provided, connect a plug for the electrical load

version (air exhaust to the outside – Fig.1B), filtering

indicated on the description label. Where a plug is

version (air circulation on the inside – Fig.1A) or with

provided, the cooker hood must be installed in order that

external motor (Fig.1C).

the plug is easily accessible.

An omnipolar switch with a minimum aperture of 3mm

SAFETY PRECAUTION

between contacts, in line with the electrical load and

local standards, must be placed between the appliance

1. Take care when the cooker hood is operating

and the network in the case of direct connection to the

simultaneously with an open fireplace or burner that

electrical network.

depend on the air in the environment and are supplied by

other than electrical energy, as the cooker hood removes

• The minimum distance between the support surfaces of

the air from the environment which a burner or fireplace

the cooking pots on the cooker top and the lowest part of

need for combustion. The negative pressure in the

the cooker hood must be at least 65 cm.

environment must not exceed 4Pa (4x10-5 bar). Provide

adequate ventilation in the environment for a safe

If a connection tube composed of two parts is used, the

operation of the cooker hood.

upper part must be placed outside the lower part.

Follow the local laws applicable for external air evacuation.

Do not connect the cooker hood exhaust to the same

conductor used to circulate hot air or for evacuating

Before connecting the model to the electricity network:

fumes from other appliances generated by other than an

- control the data plate (positioned inside the appliance)

electrical source.

to ascertain that the voltage and power correspond to

Before proceeding with the assembly operations, remove

the network and the socket is suitable. If in doubt ask a

the anti-grease filter(s) (Fig.6) so that the unit is easier

qualified electrician.

to handle.

2. WARNING !

In the case of assembly of the appliance in the suction

In certain circumstances electrical appliances may be

version prepare the hole for evacuation of the air.

a danger hazard.

FIXING TO THE WALL

A) Do not check the status of the filters while the

Drill the holes A respecting the distances indicated (Fig.2).

cooker hood is operating

Fix the appliance to the wall and align it in horizontal

B) Do not touch bulbs or adjacent areas, during or straight

position to the wall units. When the appliance has been

after prolonged use of the lighting installation.

adjusted, definitely fix the hood using the screws A (Fig.4).

C) Flambè cooking is prohibited underneath the cooker

For the various installations use screws and screw an-

hood

chors suited to the type of wall (e.g. reinforced concrete,

D) Avoid free flame, as it is damaging for the filters

plasterboard, etc.). If the screws and screw anchors are

and a fire hazard

provided with the product, check that they are suitable

E) Constantly check food frying to avoid that the

for the type of wall on which the hood is to be fixed.

overheated oil may become a fire hazard

F) Disconnect the electrical plug prior to any

If your appliance has been designed for use in habitations

maintenance.

supplied with acentralised suction device perform the

G) This appliance is not intended for use by young

following operations:

children or infirm persons without supervision

-The switch controls opening and closure of a valve

H) Young children should be supervised to ensure they

using a thermoelectical device. By placing the switch in

do not play with the appliance

the ON position, after a minute, the valve opens rotating

I) There shall be adequate ventilation of the room when

90° allowing suction of the stale air. By placing the switch

the rangehood is used at the same time as appliances

in the OFF position, the valve closes after 100 seconds.

burning gas or other fuels

L) There is a risk of fire if cleaning is not carried out in

• FIXING THE DECORATIVE TELESCOPIC FLUE

accordance with the instructions

Arrange the electrical power supply within the dimen-

sions of the decorative flue. If your appliance is to be

INSTALLATION INSTRUCTIONS

installed in the ducting version or in the version with

external motor, prepare the air exhaust opening. Adjust

Assembly and electrical connections must be carried

the width of the support bracket of the upper flue (Fig.3).

out by specialised personnel.

Then fix it to the ceiling using the screws A (Fig.3) in

such a way that it is in line with your hood and respecting

- 5 -