Maintenance
1. Cut off water and electric supplies.
2. Disconnect the heater from the tap set - see Installation - Assembly section.
GB
3. Take the lter out from the ttings at cold water inlet.
4. Clean the lter and put it back to its former position.
5. Fix the heater on the tap set.
7. Open the tap (cold and hot water) and check for leaks.
8. Vent the installation - see Venting section.
Clean the lter at least once a year and each time after the water supply has
been repaired or any water impurities have occurred.
Flow regulation
1. Open the hot water tap to the maximum water
ow rate.
2. Insert the screw driver into the regulation valve
and set the requested water ow rate.
3. Close the hot water tap.
Proper ow settings optimise unit performance. Tem-
perature of water depends on the ow rate - higher
ow rate lower water temperature.
Faults
In case the appliance does not heat the water, check for possible reasons:
- a failure of the mains supplies (e.g. fuses),
- insufcient ow rate through the heater (e.g. dirty lter, incorrect setting of the
ow regulating valve) - see „Flow regulation” section.
The guarantee does not cover the above repairs.
If there is a fault in the appliance (the heater does not work and all the above reasons
do not occur), contact the seller.
EPJ_f.372
13

Technical data
EPJ Optimus 3,5 4,4 5,5
Rated power kW 3,5 4,4 5,5
230V ~
Rated voltage
220V~
15,2
19,1
23,9
Rated current A
15,9
20,0
25,0
Min. supply water pressure MPa 0,12
1,2
1,8
2,2
Operating point l/min
1,1
1,7
2,0
Efciency (at Δt = 30°C) l/min 1,7 2,1 2,7
Overall dimension (height without tap set x width x depth) mm 218 x 214 x 95
Weight (heater with tap set) kg ~2,8 ~3,0
Fuse rated current A 16 20 25
Connection to the mains by supply cord (1,2 m)
with a plug
wires
The maximum allowed network impedance Ω 0,34 0,31
Water supply pipe section G 1/2"
Safety class IP 24
14