Kospel EPJ Optimus: GB

GB: Kospel EPJ Optimus

Safety instructions

1. Read and strictly follow the installation and operating instructions to ensure a

long life and reliable unit operation.

GB

2. The unit must be in good technical conditions and must be correctly assembled

before use.

3. The unit should always be vented before initial start-up. Vent the unit each time

after the water has been emptied from the heater or pipes (e.g. when water supply

system has been repaired or maintained).

4. The unit should be connected to electrical system and the reliability of re protec-

tion system should be tested by a qualied person.

5. The unit has to be earthed or neutrally grounded.

6. EPJ-4,4 and EPJ-5,5 must be connected to the mains through a cable box.

7. The unit must not be installed in the place which is exposed to the danger of

0

explosion and place in which the temperature may go down below 0

C.

8. The unit must be connected to the cold water supplies only.

9. Do not use when the water has been emptied from the unit or pipes (e.g. when

water supply system has been repaired or maintained).

10. Cut off power supply to the unit before you take off the product enclosure.

11. This unit can work with the tap set included in the product box only.

11. The tap set works as an air vent and therefore, cannot be connected to any valve

or a connector that is not recommended by the manufacturer.

12. Failure to install the lter on water supply pipe can cause unit damage.

13. Appropriate precaution must be taken when using hot water. Temperature of

0

water over 40

C may cause hot feeling and can be dangerous for children.

15. If the inseparable supply cord will become damage, it should be replaced at the

manufacturer or in special repair shop or by a qualied person in order to avoid

all risks.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capabilities or lack of experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

EPJ_f.372

11

Installation – Assembly

1. Fix the mixer tap set on water supply

pipe.

2. Connect the heater to the tap body

with nuts, gaskets and the lter.

3. Allow water mains pressure get to

the tap.

4. Open the tap and check for leaks.

Do it without the spray- head on.

Some impurities which come from

the installation may appear.

5. Vent the water installation.

6. Put the spray-head on.

7. Plug the heater:

EPJ-3,5 plug to an earthed socket,

EPJ-4,4 and EPJ-5,5 connect to mains

through a cable box.

Electric installation should be equipped with residual current protective de vices

and other solutions which will ensure disconnecting the heater from the source

of power (intervals between all their poles should not be less than 3mm). This

relates to EPJ-4,4 and EPJ-5,5.

Venting

1. Shut off electric supplies to the heater

2. Turn the ow on (turn the hot water tap on) in order to vent the water installation

(for about 15-30 seconds), until the ow of water becomes constant and even.

3. Shut off the ow.

4. Switch on the electric supplies.

The venting process must be repeated each time after the water has been

emptied from the unit or pipes.