Microlife BP A90: инструкция
Характеристики, спецификации
Инструкция к Тонометру Microlife BP A90
EN 1
RU 6
DE 12
TR 18
AR 24
GR 30
Microlife BP A90
EN
1
ON/OFF Button
Dear Customer,
2
Display
Your new Microlife blood pressure monitor is a reliable medical
3
Cuff Socket
instrument for taking measurements on the upper arm. It is simple
4
to use, accurate and comes highly recommended for blood pres-
Battery Compartment
sure monitoring in your home. This instrument was developed in
5
Cuff
collaboration with physicians and clinical tests proving its
6
Cuff Connector
measurement accuracy to be very high.*
AO
M-Button (Memory)
Please read through these instructions carefully so that you under-
Display
stand all functions and safety information. We want you to be
7
happy with your Microlife product. If you have any questions, prob-
Systolic Value
lems or want to order spare parts, please contact Microlife-
8
Diastolic Value
Customer Service. Your dealer or pharmacy will be able to give
9
Pulse
you the address of the Microlife dealer in your country. Alterna-
AT
Pulse Rate
tively, visit the Internet at www.microlife.com where you will find a
AK
Battery Display
wealth of invaluable information on our products.
AL
Stored Value
Stay healthy – Microlife AG!
AM
Memory Number
* This instrument uses the same measuring technology as the
AN
Heart Arrhythmia Indicator
award winning «BP 3BTO-A» model tested according to the British
Hypertension Society (BHS) protocol.
Table of Contents
1. Important Facts about Blood Pressure and Self-Measure-
ment
• How do I evaluate my blood pressure?
2. Using the Instrument for the First Time
• Inserting the batteries
• Selecting the correct cuff
3. Taking a Blood Pressure Measurement using this Instrument
4. Appearance of the Heart Arrhythmia Indicator for early
Detection
Read the instructions carefully before using this device.
5. Data Memory
• Viewing the stored values
Type BF applied part
• Memory full
• Clearing all values
1BP A90
EN
6. Battery Indicator and Battery change
Depending on physical exertion and condition, blood pressure is
• Low battery
subject to wide fluctuations as the day progresses.
You should
• Flat battery – replacement
therefore take your measurements in the same quiet condi-
tions and when you feel relaxed!
Take at least two measure-
• Which batteries and which procedure?
ments per day, one in the morning and one in the evening.
• Using rechargeable batteries
It is quite normal for two measurements taken in quick succes-
7. Error Messages
sion to produce significantly different results.
8. Safety, Care, Accuracy Test and Disposal
Deviations between measurements taken by your doctor or in
• Safety and protection
the pharmacy and those taken at home are quite normal, as
these situations are completely different.
• Instrument care
Several measurements provide a much clearer picture than
• Accuracy test
just one single measurement.
• Disposal
Leave a small break of at least 15 seconds between two
9. Guarantee
measurements.
10. Technical Specifications
If you are pregnant, you should monitor your blood pressure
very closely as it can change drastically during this time!
Guarantee Card (see Back Cover)
If you suffer from an irregular heartbeat, measurements taken
with this instrument should only be evaluated after consultation
with your doctor.
The pulse display is not suitable for checking the
1. Important Facts about Blood Pressure and Self-
frequency of heart pacemakers!
Measurement
How do I evaluate my blood pressure?
Blood pressure is the pressure of the blood flowing in the
Table for classifying blood pressure values in adults in accordance
arteries generated by the pumping of the heart. Two values, the
with the World Health Organisation (WHO) in 2003. Data in mmHg.
systolic (upper) value and the diastolic (lower) value, are
Range Systolic Diastolic Recommendation
always measured.
The instrument also indicates the pulse rate (the number of
blood pressure too low
100
60
Consult your
doctor
times the heart beats in a minute).
Permanently high blood pressure values can damage your
1. blood pressure
100 - 120 60 - 80
Self-check
optimum
health and must be treated by your doctor!
Always discuss your values with your doctor and tell him/her if
2. blood pressure normal
120 - 130 80 - 85
Self-check
you have noticed anything unusual or feel unsure. Never rely
3. blood pressure slightly
130 - 140 85 - 90
Consult your
on single blood pressure readings.
high
doctor
Enter your readings in the enclosed blood pressure diary.
4. blood pressure too
140 - 160 90 - 100
Seek medical
This will give your doctor a quick overview.
high
advice
There are many causes of excessively
high blood pressure
5. blood pressure far too
160 - 180 100 - 110
Seek medical
values
. Your doctor will explain them in more detail and offer treat-
high
advice
ment where appropriate. Besides medication, relaxation techniques,
6. blood pressure
180
110
Urgently seek
weight loss and exercise can also lower your blood pressure.
dangerously high
medical advice!
Under no circumstances should you alter the dosages of
The higher value is the one that determines the evaluation.
any drugs prescribed by your doctor!
Example: a readout value between 150/85 or 120/98 mmHg indi-
cates «blood pressure too high».
2
2. Using the Instrument for the First Time
7. The cuff will now pump up automatically. Relax, do not move
and do not tense your arm muscles until the measurement
Inserting the batteries
result is displayed. Breathe normally and do not talk.
After you have unpacked your device, first insert the batteries. The
8. When the correct pressure is reached, the pumping stops and the
battery compartment
4
is at the back of the device. Insert the
pressure falls gradually. If the required pressure was not reached,
batteries (4 x size AA 1,5 V), thereby observing the indicated polarity.
the instrument will automatically pump some more air into the cuff.
Selecting the correct cuff
9. During the measurement, the heart symbol AT flashes in the
Microlife offers different cuff sizes. Select the cuff size to match the
display and a beep sounds every time a heartbeat is detected.
circumference of your upper arms (measured by close fitting in the
10.The result, comprising the systolic
7
and the diastolic
8
blood
centre of the upper arm).
pressure and the pulse
9
is displayed and longer beep is heard.
Cuff size for circumference of upper arm
Note also the explanations on further displays in this booklet.
11.When the measurement has finished, remove the cuff.
S 17 - 22 cm (6.75 - 8.75 inches)
12.Switch off the instrument. (The monitor does switch off auto-
M 22 - 32 cm (8.75 - 12.5 inches)
matically after approx. 1 min.).
L 32 - 42 cm (12.5 - 16.5 inches)
You can stop the measurement at any time by pressing the
M - L 22 - 42 cm (8.75 - 16.5 inches)
ON/OFF button (e.g. if you feel uneasy or an unpleasant
pressure sensation).
Optional preformed cuffs «Easy» are available.
Only use Microlife cuffs.
4. Appearance of the Heart Arrhythmia Indicator for
Contact Microlife Service if the enclosed cuff 5 does not fit.
early Detection
Connect the cuff to the instrument by inserting the cuff
connector 6 into the cuff socket 3 as far as it will go.
This symbol AN indicates that certain pulse irregularities were
detected during the measurement. In this case, the result may
3. Taking a Blood Pressure Measurement using this
deviate from your normal blood pressure – repeat the measure-
Instrument
ment. In most cases, this is no cause for concern. However, if the
symbol appears on a regular basis (e.g. several times a week with
Checklist for taking a reliable measurement
measurements taken daily) we advise you to tell your doctor.
1. Avoid activity, eating or smoking immediately before the
Please show your doctor the following explanation:
measurement.
2. Sit down for at least 5 minutes before the measurement and relax.
Information for the doctor on frequent appearance of the
3. Always measure on the same arm (normally left).
Arrhythmia indicator
4. Remove close-fitting garments from the upper arm. To avoid
This instrument is an oscillometric blood pressure monitor that
constriction, shirt sleeves should not be rolled up - they do not
also analyses pulse frequency during measurement. The instru-
interfere with the cuff if they are laid flat.
ment is clinically tested.
5. Always ensure that the correct cuff size is used (marking on the
The arrhythmia symbol is displayed after the measurement, if
cuff).
pulse irregularities occur during measurement. If the symbol
Fit the cuff closely, but not too tight.
appears more frequently (e.g. several times per week on
Make sure that the cuff is positioned 2 cm above the elbow.
measurements performed daily) we recommend the patient to
The artery mark located on the cuff (ca. 3 cm long bar) must
seek medical advice.
lie over the artery which runs down the inner side of the arm.
Support your arm so it is relaxed.
The instrument does not replace a cardiac examination, but
Ensure that the cuff is at the same height as your heart.
serves to detect pulse irregularities at an early stage.
6. Press the ON/OFF button 1 to start the measurement.
3BP A90
EN
- 1
- 2