Kospel PPVE: GB
GB: Kospel PPVE

Safety instructions
1. Read and strictly follow the installation and operating instructions to ensure a
long life and reliable unit operation.
GB
2. The unit is designed to be wall mounted.
3. The unit can only be used when in perfect technical condition and correctly
assembled.
4. If there is a non-return valve installed on the water supply pipe the safety valve
must be tted between unit and non-return valve. This relates to KDE only.
5. Inlet and outlet pipes should not be made of plastic. This relates to KDE only.
0
6. The maximum inlet water temperature should not exceed 70
C.
7. The unit should always be vented before initial start-up. Vent the unit each time
after the water has been emptied from the heater or pipes (e.g. when water
supply system has been repaired or maintained).
8. Connection to the mains and measurement of re protection effectiveness
should be made by a qualied person.
9. The unit has to be earthed.
10. The unit must be permanently connected to the mains which is equipped with
earth clamp.
11. Electric installation should be equipped with residual current protective devices
and other solutions which will ensure disconnecting the heater from the source
of power (intervals between all their poles should not be less than 3 mm).
12. The unit must not be installed in the place which is exposed to the danger of
0
explosion and place in which the temperature may go down below 0
C.
13. The unit must be kept in a place in which the temperature never go down below
0
0
C (there is a water inside the unit).
14. Do not use when the water has been emptied from the unit or pipes (e.g. when
water supply system has been repaired or maintained).
15. Unit’s cover must not be taken off while power is on.
16. Failure to install the lter on water supply pipe can cause unit damage.
17. Appropriate precaution must be taken while using hot water. Temperature of
0
water over 40
C may cause hot feeling and can be dangerous for children.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instructions concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
PL,DE,GB,RU-045AB/f.453
21

Installation – Assembly
3
1. Apply templete on place the unit will be
2
1
tted. Mark points for drilling the holes for
xing screws.
2. Bring the water system pipes and electric
supply cables to the marked places.
3. Take off the unit’s cover.
4. Run the supply wire through the hole and
x the unit on the wall.
5. Connect the unit to the electric mains.
6. Remove rubber plugs from cold and hot
water ttings.
7. Connect the unit to the water supply system.
8. Open the cold water valve and check for
leaks.
9. Vent the water system. See section „Venting
”
10. Make sure that the WC3 or WT3 temp. lim-
iter is at working position (the knob should
be pushed in).
11. Put the unit’s cover back.
12. Make sure that there is no access to live
parts through the holes at the back plate.
Safety temperature limiter
a) b)
WC3/WT3
a) to switch on
b) WC3/WT3 on
Venting
1. Shut off electric supplies to the heater
2. Turn the ow on (turn the hot water tap on) in order to vent the water installation
(for about 15-30 seconds), until the ow of water becomes constant and even.
3. Switch on the electric supplies.
22