INDEX 

Precaution Notice ................................................................................................................ 1 

ENERMAX Platimax series Power Supply Specification .................................................. 2 

ENGLISH............................................................................................................................ 3 

DEUTSCH .......................................................................................................................... 7 

ESPAÑOL .......................................................................................................................... 11 

FRANCAIS ....................................................................................................................... 15 

ITALIANO ........................................................................................................................ 19 

РУССКИЙ

 ........................................................................................................................ 23 

POLSKI ............................................................................................................................. 27 

日本語

 ............................................................................................................................... 31 

 ........................................................................................................................... 35 

中文

 ................................................................................................................................... 39 

正體中文

 ........................................................................................................................... 43 

ไ ท ย

 .................................................................................................................................. 47 

INDONESIA…… ............................................................................................................. 51 

background image

1

Precaution Notice

Only  a  technician,  authorized  by  ENERMAX,  is  allowed  to  perform  maintenance  service! 

Warranty is subject to void under unauthorized attempt to open the power case or modification of 

any kinds, even attempted only, of the power supply or its components! 

ENERMAX will not be responsible for damages caused by following situations: 

Opening  of  the  PSU  case  and/or  modification  of  any  component  or  cable  without 

ENERMAX’s written authorization. 

Ignoring connector’s wrong insertion prevention design by attaching a connector to a device 

in wrong orientation. 

Connecting too many devices to one cable unit by using additional adaptor (Y cables). 

Usage of non-genuine ENERMAX modular cables. 

The serial number label or warranty seal is defaced, modified, or removed. 

Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, 

fire, earthquake, etc. 

This  ENERMAX  Technology  Corporation  product  is  warranted  to  be  free  from  defects  in 

material and workmanship for a period of five (5) years from the date of purchase. ENERMAX 

Technology  Corporation  agrees  to  repair  or  replace  the  product,  at  its  own  option  and  at  no 

charge,  if,  during  the  warranty  period,  it  is  returned  to  nearest  ENERMAX  Technology 

Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandize 

authorization (RMA) number, and if inspection reveals that the product is defective. Charges for 

removing or installing the product are excluded under the terms of this warranty agreement. This 

warranty shall not apply to any product, which has been subject to connection to a faulty power 

source, alteration, negligence, or accident, or to any product, which has been installed other than 

in accordance with these instructions. In no event shall ENERMAX Technology Corporation, or 

its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding 

the purchase price of this product! 

If  you  are  uncertain  whether  or  not  your  ENERMAX  PSU  is  defective,  please  contact  your 

dealer/reseller for support!

Web Site: http://www.enermax.com 

E-mail: enermax@enermax.com.tw

Forum: forum.enermax.com 

ENERMAX  Technology  Corporation,  15F-2,  No.  888,  Jing-Guo  Road,  Taoyuan  City  (330),  Taiwan  (R.O.C.),  Tel. 

+886-3-316-1675, Fax. +886-3-346-6640 

©2011 ENERMAX Technology Corporation. All rights reserved. Specifications are subject to change without prior notice. Actual 

product and accessories may differ from illustrations. Omissions and printing errors excepted. Content of delivery might differ in 

different countries or areas. Some trademarks may be claimed as the property of others. Reproduction in any manner without the 

written permission of ENERMAX is strictly forbidden.

background image

2

ENERMAX Platimax Series Power Supply Specification 

EPM1000EWT 

AC Input Voltage 

115-240VAC, 50-60Hz 

(Maximum range: 103-264VAC, 47-63Hz) 

AC Input Current 

10.5-4.5A 

DC Output 

Rated 

Combined 

3.3V 

0-20A 

100W 

5V 

0-20A 

12V 

0-83A 

996W 

-12V 

0-0.5A 

6W 

5Vsb 

0-3A 

15W 

Total Power 

1000W 

Peak Power* 

1100W 

Protection Circuit 

Over Current Protection

DC Rail

OCP trigger range 

3.3V 

30 – 40A 

5V 

30 – 40A 

(DC) 

Under Voltage / Over Voltage 

Protection 

DC Rail 

UVP trigger range  OVP trigger range 

3.3V 

2.0 – 2.4V 

3.9 – 4.5V 

5V 

3.3 – 3.7V 

5.7 – 6.5V 

12V 

8.5 – 9.5V 

13.3 – 14.5V 

Over Power Protection 

Activated when output power > 120 ~150% of rated max load. 

Over Temperature Protection 

Activated when PSU heat sink > 90 ~ 120

o

C. 

Short Circuit Protection 

Activated when any DC rails short-circuited. 

ENVIRONMENT 

Temperature 

Operation ambient: 0~50

o

Storage ambient: -40~70

 o

Humidity 

Operation: to 85% relative humidity, non-condensing at 25

 o

Storage: to 95% relative humidity, non-condensing at 50

 o

OTHERS 

MTBF 

> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25

 o

(MIL-HDBK-217F standard) 

Dimension 

150 (w) x 86 (h) x 175 (d) mm 

Weight 

2.25kg (without modular cables) 

±

50g 

Safety 

UL/cUL(Level 6), TUV, GOST, CB, BSMI 

EMC 

CE, FCC, KCC 

*

 Peak power may last up to 60 seconds.

background image

3

User’s Manual 

Dear customer, 

Thank you for choosing this ENERMAX power supply unit (PSU)! Please read this manual carefully and 

follow its instructions before installing the PSU. 

We would like to draw your attention that a computer required very specific conditions to work best for 

you without failing. To avoid failures and to increase lifetime of the system, we suggest that: 

Your system is NOT located near a radiator or any other heat producing device 

Your system is NOT located near a magnetic device 

Your system is NOT located in a moist and/or dusty and/or vibrating environment 

Your system is NOT exposed to direct sunshine 

Your system is sufficiently cooled by additional fans 

If you use AC extension cables, please make sure it can support all connected appliances’ potential 

peak power draw. Or redistribute other high power consumption equipment, such as laser printers or 

monitors to other AC wall outlets. Exceeding the extension cable’s loading capacity could trigger its 

circuit breaker and cut off the power. 

If you want to add the UPS (Uninterruptible Power Supply) for your system, please choose adequate 

Watts/VA capacity UPS. Ex.

PSU Model 

Suggested minimum UPS output power capacity 

(Based on efficiency & PFC at respective load) 

EPM1000EWT 

1100W / 1600VA 

If  you  intend  to  add  other  appliance  powered  by  the  same  UPS,  such  as  monitor  or  printer, 

please use higher capacity UPS according to all connected devices’ rated power draw. 

Please do not mistake VA capacity as Watts, or use insufficient power UPS. This would result 

in

less UPS battery runtime or the inability to power the system in battery mode.

NAME OF PARTS 

Output cable: Please check “Cables & 

Connectors” section. 

Fan. 

# 1

Honeycomb air vent.

 # 1

ON/OFF switch (I=ON, O=OFF). 

# 2 

AC Inlet.

 # 2

   

CordGuard. 

#3

#1 To ensure best system cooling, do not block PSU fan’s air in-take and air vent area. 

This PSU offers a special HeatGuard function. When the system is turned off, or goes into ACPI 

S3/S4 sleep mode, the PSU fan will keep dissipating the remaining heat for 30 ~ 60 seconds and 

prolonging system lifetime. 

#2  When  assembling  or  maintaining  the  system,  please  remove  AC  cord  from  AC  inlet,  or  turn 

ON/OFF switch into “OFF” position. Then you can safely service the system.

#3 AC cord can get loose in many ways. The ENERMAX CordGuard lock can fix your AC cord tightly 

to the PSU, so that it will not be easily detached and avoid shut-downs of your PC. The following 

is CordGuard installation: 

background image

4

Set your PSU into the chassis, and please 

make sure the 

I/O switch is 

on “O” 

position. 

Press two sides of the CordGuard lock 

together, and set it into 

CordGuard holder near 

the AC inlet. 

Plug the AC 

cord into your 

PSU. 

Lock CordGuard to 

latch onto AC cord. 

1.

CordGuard is for AC cords supplied with ENERMAX CordGuard-compatible PSUs. Other AC 

cords may be incompatible. 

2.

When assembling or maintaining the system, please remove AC cord from AC inlet, or turn I/O 

switch into “O” position.   

CABLES & CONNECTORS 

All  connectors  are  designed  to  prevent  insertion  in  wrong  orientation.  If  you  cannot  easily  insert  a 

connector, please check if you are inserting the connector in the right orientation. Do not try by force to 

insert  it  nor  modify  the  connectors.  This  might  damage  power  supply  and  system  components,  and 

warranty shall be void. 

Following graphic illustrates the modular sockets layout and its DC rail distribution.

12P RED sockets 

The red sockets provide 12V for modular cable 

to power graphics card, CPU or RAM. 

5P BLACK sockets 

The black sockets provide 3.3V/5V/12V for 

modular cable to power drives or other 

peripheral. 

This  product  incorporates  multiple  12V  rails  over  current protection. If  you  let  many  peripherals 

consume the power on only one 12V rail, it may trigger the over current protection and shut down 

the  system.  Please  re-direct  certain  peripheral power  cable  to  other  12V  rail  to  share  the  current 

loading to ensure highest stability and safety. 

background image

5

CONNECTOR TYPES 

24P Mainboard 

For new generations of ATX/EEB/CEB server/workstation MB. 

8P CPU +12V 

8-pin configuration supports multi-CPU server/workstation systems and some 

single extreme CPU systems.

4+4P(8P) CPU+12V, in combined mode 

8-pin  configuration  supports  multi-CPU  server/workstation  systems  and  some 

single extreme CPU systems.

4+4P(8P) CPU+12V, in split mode 

4-pin configuration supports certain single CPU systems. Some multi-CPU 

workstation/server system might also need this extra 4-pin 12V connector. 

Please use the connector with “12V” marking.

6+2P (8P) PCI Express, in combined mode 

8-pin  configuration  supports  latest  extreme  graphic  cards,  which  require  8-pin 

PCI-E connector.

6+2P (8P) PCI Express, in split mode / 6P PCI Express 

6-pin configuration supports most performance PCI-E graphic cards, which require 

6-pin PCI-E connector.

SATA

# 1

For SATA/SAS drives.   

4P Molex

# 2 

For IDE/SCSI/SAS drives or some AGP graphic card with traditional 4P power in 

socket. 

FDD 

For floppy drive or certain add-on card.

#1  Some  SATA  drives  might  accept  SATA  or  4P  Molex  power.  Normally,  use  either  one  of  power 

connector to power the driver, BUT NOT BOTH! Please check the drive’s manual for details. 

#2 Some MB might require this connector to share the +12V current from 24-pin Mainboard connector to 

PCI-E  slot.  If  your  system  has  multiple  extreme  graphic  cards,  please  plug  this  connector  to  MB 

correspond socket and check the MB’s manual for details.   

MODULAR CABLES SUPPLIED 

Use  ONLY  genuine  ENERMAX  modular  cables  coming  with  ENERMAX  PSU.  Third  party  cables 

might not be compatible and might cause damage to your PSU and/or system, and use of third party 

cable shall void PSU warranty.

EMC014-G: 2 x 6+2P (8P) PCI-E 2.0 

Modular  cable  for  1  or  2  performance  PCI  Express  graphic  cards,  which 

needs 6P or 8P PCI-E connector. 

EMC019-G: 4 x SATA drives 

Modular cable for SATA/SAS drives like ODD and HDD. 

EMC020-G : 4 x 4P Molex (IDE/SCSI) drives & 1 x FDD connector 

Modular cable for IDE/SCSI/SAS drives and peripheral, plus 1 FDD power 

connector. 

background image

6

EMC021-G: 2 x SATA & 2 x 4P Molex

Modular cable for SATA/SAS/IDE/SCSI drives and other peripherals.

Special note for System Integrators:

 If your system requires special modular cable configuration or 

design, please contact an ENERMAX sales representative.

ATTACHING / DETACHING THE MODULAR CABLES 

Attaching the modular cable to PSU 

5-pin / 12-pin connector on modular cable and PSU’s modular socket has an 

arrow mark. To make correct connection is easy: 

1.

Black connector to black socket, and red to red. 

2.

Arrow mark to arrow mark. 

3.

Then you can easily plug in the connector. 

Detaching the modular cable from PSU 

5-pin / 12-pin connector on modular cable has two hooks to lock with the 

PSU’s modular sockets. When unplug the modular cable from PSU, please 

press two hooks together and gently pull out the cable. 

BOOTING YOUR SYSTEM 

Before booting your system, please check that: 

1.

Main power connector (24P) is properly connected. 

2.

CPU +12V power connector (4 or 8P configuration), and/or a 4P Molex connector (if required by 

MB) is properly connected. 

3.

All other needed connectors are properly connected. 

4.

AC cord is properly connected to wall outlet and PSU AC inlet. 

5.

Close your system chassis. 

6.

Turn on the PSU by switching the ON/OFF switch to “ON”, and your system is ready. 

PROTECTION, SAFETY & SECURITY 

This  ENERMAX  PSU  features  multiple  protections.  In  case  of  most  abnormal  situations,  the  power 

supply  will  automatically  turn  off  to  avoid  potential  danger  to  itself  and  other  PC  components.  It  is 

usually  a  malfunction  of  components  or  user’s  negligence  to  trigger  off  a  protection  event.  In  such 

circumstance, please check your PC devices and working environment for malfunction: 

1.

Turn  I/O  switch  of  power  supply  into  “O”  position,  or  disconnect  AC  cord  from  wall  plug  and 

power supply AC inlet. 

2.

Check  PSU  for  temperature  by  simply  touching  it.  If  it  is  very  hot,  this  can  be  caused  by 

malfunction of case fans or the PSU fan itself and/or wrong positioning of your PC. 

3.

Wait some minutes until PSU cools off. 

4.

Reconnect AC cord to wall plug and power supply AC inlet. 

5.

Turn I/O switch of power supply into “I” position, and reboot your system. 

6.

Check, if all fans are working. 

7.

Contact technical support of the respective manufacturer of the component which you think might 

be the cause to the problem. (e.g. MB, GPU or PSU) 

If  you  have  any  question  or  need  support,  please  contact  your  reseller  or  nearest  ENERMAX 

subsidiary/agent or ENERMAX headquarter service center. 

©2011 ENERMAX Technology Corporation. All rights reserved. Specifications are subject to change without prior notice. Actual 

product and accessories may differ from illustrations. Omissions and printing errors excepted. Content of delivery might differ in 

different countries or areas. Some trademarks may be claimed as the property of others. Reproduction in any manner without the 

written permission of ENERMAX is strictly forbidden.

background image

7

Benutzerhandbuch 

Sehr geehrte Kundin, sehr geehrter Kunde, 

Vielen Dank, dass Sie sich für dieses ENERMAX-Netzteil (PSU) entschieden haben! Bitte lesen Sie sich 

dieses  Handbuch  sorgfältig  durch  und  folgen  Sie  bitte  seinen  Anweisungen  bevor  Sie  das  Netzteil 

installieren! 

Wir  möchten  Sie darauf  hinweisen,  dass  moderne  Systeme  sehr empfindlich  geworden  sind  und  genau 

definierte Bedingungen benötigen, um optimal ohne Ausfälle arbeiten zu können. Um solche Ausfälle zu 

vermeiden und die Lebensdauer Ihres Systems zu verlängern, empfehlen wir Ihnen sicherzustellen, dass: 

Ihr System nicht neben einer Heizung oder einer anderen Wärmequelle steht. 

Ihr System nicht neben einer magnetischen Quelle steht. 

Ihr System nicht in einer feuchten und/oder staubigen und/oder vibrierenden Umgebung steht. 

Ihr System nicht dem direkten Sonnenlicht ausgesetzt ist. 

Ihr System ausreichend durch Lüfter gekühlt wird. 

Falls Sie ein Verlängerungskabel verwenden, stellen Sie bitte sicher, dass dieses dazu geeignet ist, 

den  maximalen  Strombedarf  sämtlicher  angeschlossenen  Geräte  zu  leisten.  Andernfalls  schließen 

Sie bitte weitere viel Strom verbrauchende Geräte (wie Laserdrucker oder Monitor) an eine andere 

Steckdose  an.  Ein  Überschreiten  der  maximalen  Durchleitungsfähigkeit  des  Verlängerungskabels 

könnte zu einem Auslösen der Sicherung führen. 

Falls  Sie  eine  USV  (Unterbrechungsfreie  Stromversorgung)  verwenden  möchten,  nutzen  Sie  bitte 

eine mit ausreichender Watt/VA-Kapazität. Z. B.: 

PSU Modell 

Empfohlene kleinste USV-Kapazität 

(gemäß Effizienz & PFC bei entsprechender Last) 

EPM1000EWT 

1100W / 1600VA 

Falls Sie andere Geräte wie Monitor oder Drucker gleichfalls an die selbige USV anschließen 

möchten,  wählen  Sie  bitte  eine  USV  mit  höherer  Kapazität  gemäß  der  Summe  der 

Leistungsaufnahme aller angeschlossenen Geräte. 

Bitte  verwechseln  Sie  nicht  VA  mit  Watt  und  nutzen  Sie  bitte  eine  ausreichende  USV. 

Andernfalls verkürzt sich die Laufzeit der Batterie und gefährdet die Versorgung des Systems 

im Batterie-Modus. 

DETAILBESCHREIBUNG 

Ausgangskabel: Bitte lesen Sie den Abschnitt 

„Kabel & Anschlüsse“. 

Lüfter. 

# 1

Honigwabenluftauslass.

 # 1

I/O Schalter*: separater Netzteil An/Aus-Schalter 

(I=AN, O=AUS). 

# 2

Stromeingang.

# 2

CordGuard 

# 3

#1 Bitte blockieren Sie nicht die Lufteinlässe/Luftauslässe, um eine bestmögliche Systemkühlung zu gewährleisten. 

Dieses PSU verfügt über eine besondere HeatGuard-Funktion: Wenn das System abgeschaltet oder in den ACPI 

S3/S4  Schlafmodus  gebracht  wird,  wird  der  PSU-Lüfter  die  Restwärme  für  30-60  Sek.  abführen  und  so  die 

Lebensdauer des Systems verlängern. 

#2 Entfernen Sie immer das Stromkabel vom Netzteil, schalten Sie den I/O-Schalter auf „O“ und warten Sie, bevor 

Sie am System arbeiten. 

background image

8

#3 Der Netzstecker kann sich auf unterschiedliche Weise lösen. Der ENERMAX-CordGuard fixiert den Stecker am 

Netzteil. Er verhindert unfreiwillige Systemabstürze durch einen versehentlich gezogenen Netzstecker.

Setzen Sie das Netzteil in das Gehäuse 

ein. Stellen Sie sicher, dass der 

Netzschalter auf 

“O“ (Aus) steht. 

Drücken Sie die beiden Seiten des 

CordGuard zusammen und befestigen Sie ihn 

an der dafür vorgesehenen Stelle. 

Schließen Sie das Netzkabel am Netzteil 

an. 

Klappen Sie den CordGuard herunter und 

sichern Sie auf diese 

Weise den Netzstecker. 

1.

Der CordGuard ist  nur  f

ü

r Netzkabel  geeignet, die  mit CordGuard-kompatiblen ENERMAX-Netzteilen 

ausgeliefert wurden. Andere Netzkabel sind mit dem ENERMAX-CordGuard ggf. nicht kompatibel. 

2.

Beim Zusammenbauen oder bei der Wartung des Systems ziehen  Sie bitte immer den  Netzstecker oder 

stellen Sie den Netzschalter auf “O“(Aus).

KABEL & ANSCHLÜSSE 

Alle  Sockel  und  Anschlüsse  sind  so  entworfen,  dass  ein  Anschluss  in  falscher  Ausrichtung  nahezu 

unmöglich ist. Der Anschluss an die kompatiblen Sockel gestaltet sich leichtgängig und ohne größeren 

Widerstand. Wenn Sie einen originalen ENERMAX Anschluss nicht auf Anhieb mit einer Komponente 

verbinden können, überprüfen Sie bitte, ob Sie die richtige Ausrichtung gewählt haben. Versuchen Sie es 

keinesfalls mit Gewalt! Verändern Sie nicht die Anschlüsse! Dies könnte das Netzteil beschädigen und hat 

das Erlöschen der Garantie zur Folge! 

Folgende Grafik illustriert das Layout der modularen Sockel und deren DC Leitungsverteilung. 

Rote 12-Pin Sockel 

Rote Sockel (12V) für modulare Kabel der 

Grafikkarten, CPUs oder RAM. 

Schwarze 5-Pin Sockel 

Schwarze Sockel (3.3V/5V/12V) für 

modulare Kabel der Laufwerke (HDD, ODD) 

oder Peripheriegeräte. 

Dieses  Netzteil  besitzt  eine  Überstromsicherung  (OCP)  auf  jeder  einzelnen  12V-Leitung.  Wenn  zu  viele 

Komponenten  an  einer  12V-Leitung  angeschlossen  werden,  kann  es  zur  Auslösung  der  Überstromsicherung 

kommen.  Daher  achten  Sie  bitte  auf  eine  gleichmäßige  Verteilung  der  Komponenten  auf  die  einzelnen 

12V-Leitungen, um optimale Stabilität und Sicherheit zu gewährleisten. 

background image

9

Anschlusstypen 

24P Mainboard 

Für die neueste Generation von ATX/EEB/CEB Server/Workstation MB’s. 

8P CPU +12V 

Unterstützt Multi-CPU Server/Workstation-Systeme und einige Ein-Sockel 

Systeme.

4+4P (8P) CPU +12V, in “kombiniertem Modus” 

Unterstützt Multi-CPU Server/Workstation-Systeme und einige 

Hochleistungs-Einzel-CPU Systeme. 

4+4P (8P) CPU +12V, in “getrenntem Modus”

4-Pin Konfiguration unterstützt herkömmliche Einzel-CPU Systeme. Einige 

Multi-CPU Systeme benötigen möglicherweise ebenfalls diesen zusätzlich 

Stecker. 

Bitte verwenden Sie das Modul mit der „+12V” Markierung. 

6+2P (8P) PCI Express, in “kombiniertem Modus” 

8-pin Konfiguration unterstützt die neuesten Grafikkarten, welche diesen 8-Pin 

PCI-E Stecker benötigen.

6+2P (8P) PCI Express, in “getrenntem Modus” / 6P PCI Express

    

6-Pin Konfiguration unterstützt die meisten Grafikkarten, welche diesen 6-Pin 

PCI-E Stecker benötigen.

SATA

# 1

Für SATA/SAS-Laufwerke.     

4P Molex

# 2 

Für IDE/SCSI/SAS-Laufwerke oder einige AGP Grafikkarten mit traditionellem 

4-Pin Stecker. 

FDD 

Für Floppy-Laufwerke oder einige Erweiterungskarten.

#1  Einige  SATA-Laufwerke  unterstützen  SATA  &  4-Pin  Molex  Stecker.  Schließen  Sie  nur  einen  Stecker  an! 

Lesen Sie ansonsten im Handbuch des Laufwerks nach! 

#2 Bei  einigen  Mainboards  reicht  die  Spannung  des  24-Pin-Mainboard-Steckers  nicht  für  die  Stromversorgung 

von  Grafikkarten  im  PCI-E-Slot  aus  (wenn  Sie  z.  B.  ein  System  mit  mehreren  hochleistungsfähigen 

Grafikkarten  betreiben).  Der  Anschluss  eines  zusätzlichen  4-Pin-Molex-Steckers  ist  erforderlich.  Details 

entnehmen Sie bitte dem Benutzerhandbuch des Mainboards. 

MODULARE KABEL (im Lieferumfang enthalten) 

Benutzen Sie nur original ENERMAX modulare Kabel für dieses PSU. Andere Kabel könnten das PSU 

und Ihr System beschädigen und den Garantieverlust zur Folge haben! 

EMC014-G: 2 x 6+2P (8P) PCI-E 2.0 

Modulares Kabel für 1 oder 2 Performance PCI Express Grafikkarten, 

welche 6P oder 8P PCI-E Stecker benötigen.

EMC019-G: 4 x SATA drives 

Modulares Kabel für SATA/SAS-Laufwerke wie ODD und HDD. 

EMC020-G : 4 x 4P Molex (IDE/SCSI) drives & 1 x FDD connector 

Modulares Kabel für IDE/SCSI/SAS-Laufwerke und Peripheriegeräte + 

1x FDD-Anschluss. 

EMC021-G: 2 x SATA & 2 x 4P Molex 

Modulares Kabel für SATA/SAS/IDE/SCSI-Laufwerke und 

Peripheriegeräte. 

background image

10 

Die im Lieferumfang enthaltenen modularen Kabel können je nach Modell und Region variieren. 

Wir bieten weitere optionale Kabel an. Bitte besuchen Sie unsere Webseite: www.enermax.de. 

Besonderer Hinweis für Systemintegratoren: 

Falls Ihr System besondere modulare Kabelkonfigurationen 

oder Designs benötigt, sprechen Sie bitte mit einem ENERMAX Vertriebsbeauftragten. 

VERBINDEN & ENTFERNEN VON MODULAREN KABELN 

Modulare Kabel an das Netzteil anschließen 

Die 5-Pin / 12-Pin Stecker auf den modularen Kabeln und den Sockeln des Netzteils 

haben weiße Pfeilmarkierungen. 

Folgende Regeln machen die Anwendung einfach: 

1.

Schwarze Stecker zu schwarzen Sockeln und rote zu roten. 

2.

Pfeilmarkierung zu Pfeilmarkierung. 

Modulare Kabel vom Netzteil entfernen 

Alle  5-Pin  /  12-Pin  Stecker  auf  den  modularen  Kabeln  haben  zwei  Haken  zum 

Einrasten  mit  den  Sockeln  des  Netzteils.  Um  ein  modulares  Kabel  zu  entfernen, 

pressen Sie bitten gegen die zwei Haken und ziehen Sie den Stecker dann sanft heraus. 

EINSCHALTEN IHRES SYSTEMS 

Vor dem Einschalten Ihres Systems stellen Sie bitte sicher, dass: 

1.

Mainboard-Stromanschluss (24P) korrekt angeschlossen ist. 

2.

CPU +12V ATX Stromanschluss (4 oder 8 Pin Konfiguration) (falls für MB erforderlich) 

korrekt angeschlossen ist, oder ein 4-Pin Molex-Stromanschluss (falls für MB erforderlich) 

korrekt angeschlossen ist. 

3.

Alle anderen erforderlichen Stromanschlüsse korrekt angeschlossen sind. 

4.

Kaltgerätekabel (Stromkabel) korrekt an Steckdose und Netzteil angeschlossen ist. 

5.

Das Systemgehäuse verschlossen und verschraubt ist! 

6.

Drücken Sie am Netzteil den I/O-Schalter auf “I” (ON). Das System ist jetzt bereit! 

SICHERHEITSFUNKTIONEN 

Dieses ENERMAX Netzteil verfügt über zahlreiche Sicherheitsfunktionen. Im Fall der meisten abnormen 

Situationen wird sich das Netzteil zum Schutz  Ihres gesamten PC-Systems automatisch abschalten, um 

Schäden  zu  vermeiden.  In  den  meisten  Situationen,  in  denen  dies  geschieht,  ist  eine 

Komponenten-Fehlfunktion  oder  Fehlverhalten  die  Ursache.  In  einer  solchen  Situation  prüfen  Sie  bitte 

zuerst ihre PC-Komponenten und die Umgebung auf Fehlfunktion(en), indem Sie folgendes ausschalten 

und/oder abtrennen: 

1.

I/O Schalter des Netzteils auf “O“ & Kaltgerätekabel (Stromkabel) von der Steckdose und vom 

Netzteil trennen. 

2.

Berühren Sie das Netzteil vorsichtig, um zu prüfen, ob es stark erhitzt ist. Sollte dies der Fall 

sein, kann es eine Folge der Fehlfunktion von Gehäuse-oder Netzteillüftern sein oder durch eine 

ungenügende Anzahl von Gehäuselüftern oder eine falsche PC-Positionierung verursacht 

worden sein. 

3.

Warten Sie einige Minuten, bis sich das Netzteil abgekühlt hat. 

4.

Schliessen Sie wieder das Kaltgerätekabel (Stromkabel) an Steckdose und Netzteil an. 

5.

Schalten Sie den I/O-Schalter am Netzteil auf “I”. 

6.

Prüfen Sie nun, ob alle Lüfter Ihres Systems arbeiten. 

7.

Kontaktieren Sie bitte den technischen Support des Herstellers der Komponente, von der Sie 

glauben, dass Sie die Fehlfunktion verursacht (z.B. MB, Grafikkarte oder ENERMAX-Netzteil). 

Falls  Sie  Fragen  haben  oder  Support  benötigen,  wenden  Sie  sich  bitte  an  Ihren  Händler,  Ihre  nächste 

ENERMAX-Niederlassung, deren Agenten oder an das ENERMAX Headquarter Service Center! 

Schnelle Hilfe bei allen Fragen zu ENERMAX-Produkten erhalten Sie auch online im internationalen ENERMAX-Support-Forum: 

http://forum.enermax.com. 

Аннотация для Enermax Platimax EPM1000EWT в формате PDF