PowerWalker VI 650 LCD: instruction
Class: Equipment
Type:
Manual for PowerWalker VI 650 LCD

EN
LineInteractiveUPS
PowerWalkerVI450LCD
PowerWalkerVI650LCD
PowerWalkerVI850LCD
PowerWalkerVI1000LCD
PowerWalkerVI1500LCD
PowerWalkerVI2000LCD
QuickStartGuide
EN/DE/FR/ES/IT/PT/SE/FI/NO/TR
RU/UA/BY/PL/CZ/HR/HU/BG/KZ/SR

IMPORTANTSAFETYINSTRUCTIONS
EN
SAVETHESEINSTRUCTIONS–Thismanualcontainsimportantinstructionsformodels
PowerWalkerVI450/650/850/1000/1500/2000LCDthatshouldbefollowedduringinstallation
andmaintenanceoftheUPSandbatteries.
• ThisproductisspeciallydesignedforPCsanditisnotrecommendedforuseinanylife‐
supportingsystemandotherspecificimportantequipment.
• Thisequipmentcanbeoperatedbyanyindividualwithnoprevioustraining.
• DonotplughouseholdappliancessuchashairdryerstoUPSreceptacles.
• Thisunitintendedforinstallationinacontrolledenvironment(temperaturecontrolled,
indoorareafreeofconductivecontaminants).AvoidinstallingtheUPSinlocationswhere
thereisstandingorrunningwater,orexcessivehumidity.
• Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer
servicing
toqualifiedservicepersonnel.
• Theutilitypoweroutletshallbeneartheequipmentandeasilyaccessible.ToisolateUPS
fromACinput,removetheplugfromtheutilitypoweroutlet.
• IfUPSistobestoredforalongtime, it isrecommendedto recharge the batteries(by
connecting
theutilitypowertoUPS,switch“ON”),onceamonthfor24hourstoavoida
fullbatterydischarge.
• PleasedonotusetheUPSinexcessoftheratedloadcapacity.
• The UPS contains one/two large‐capacity batteries. So the shell shall not be opened,
otherwise such
dangers as electric shock will be caused. If any internal overhaul or
replacementofthebatteryisrequired,pleasecontactthedistributor.
• TheinternalshortcircuitingoftheUPSwillleadtodangerssuchaselectricshockorfire,
therefore,nowatercontainers(suchasawaterglass)shallbe
placedonthetopofthe
UPSsoastoavoidsuchdangersaselectricshock.
• Donotdisposeofbatteryorbatteriesinafire.Thebatterymayexplode.
• Donotopenormutilatethebatteryorbatteries.Releasedelectrolyteisharmfultothe
skinandeyes.
Itmaybetoxic.
• IconΦontheratinglabelstandsforphasesymbol.
• A battery can present a risk of electrical shock and high short circuit current. The
followingprecautionsshouldbeobservedwhenworkingonbatteries:
• Removewatches,rings,orothermetalobjectsfromthehand.
• Usetoolswithinsulatedhandles.

• Servicingofbatteriesshouldbeperformedorsupervisedbypersonnelknowledgeableof
batteries and the required precautions.Keep unauthorized personnel away from
EN
batteries.
• Whenreplacingbatteries,replacewiththesametypeandnumberofthesealedlead‐acid
batteries.
• Themaximumambienttemperatureratingis40°
C.
• This pluggable type A equipment with battery already installed by the supplier is
operatorinstallableandmaybeoperatedbylaymen.
• Duringtheinstallationofthisequipmentitshouldbeassuredthatthesumoftheleakage
currentsoftheUPSandtheconnectedloadsdoesnotexceed
3.5mA.
• Attention, hazardous through electric shock. Also with disconnection of this unit from
the mains, hazardous voltage stillmay beaccessible through supply from battery.The
battery supply should be therefore disconnected in the plus and minus pole of the
batterywhenmaintenanceorserviceworkinsidetheUPS
isnecessary.
• ThemainssocketoutletthatsuppliestheUPSshallbeinstalledneartheUPSandshallbe
easilyaccessible.
• In case smoke is found coming out from the device, please cut off the power supply
quicklyandcontactthedistributor.
• Donotkeeporusethis
productinanyofthefollowingenvironments:
o Anyareawithcombustiblegas,corrosivesubstanceorheavydust.
o Anyarea with extraordinarily high orlow temperature (above40˚C or below
0˚C)andhumidityofmorethan90%.
o Anyareaexposedtodirectsunshineornearany
heatingapparatus.
o Anyareawithseriousvibrations.
o Outdoor.
• Intheeventthatthereisfireoccurringinthevicinity,pleaseusedry‐powerextinguishers.
Theuseofliquidextinguishersmaygiverisetothedangerofelectricshock.
ThisproductcomplieswiththesafetyandenvironmentalregulationsinEU.
Ifthetimearisestothrowawayyourproduct,pleaserecycleallthecomponentspossible.Batteries
andrechargeablebatteriesarenottobedisposedinyourdomesticwaste!Pleaserecyclethemat
yourlocalrecyclingpoint.Togetherwecanhelptoprotecttheenvironment.

1.Introduction
EN
PowerWalker VI seriesis an intelligent and compact line interactiveUPS (UninterruptiblePower
Supply)which isdesignedto protect your personalcomputeror sensitive electronicequipments
fromallformsofpowerinterference,includingcompletepowerfailures.Itisequippedwithmany
featuresthatallowanyattachedequipmenttooperatelongerand
morereliability.
2.Greenconceptdesign
PowerWalker VI 450/650/850/1000/1500/2000 LCD series adopt switching mode charging which
createsavarietyofbenefits:
• Increaseschargingefficiencytomorethan80%,moreenergysavingthantraditionalUPS
• Thebatteryrequiresonly4hourstobe90%charged,reducing50%ofchargingtime
• Reducesheatgenerationduring
batterycharging,providingalongerbatterylife
• Increasesreliabilityandhelpstosavemoney
3.PackageContent s
Youshouldhavereceivedthefollowingitemsinsideofpackage:
UPSUnit USBCable IECCable
ACInputPowerCord
(forVI1000/1500/2000
(forVI1500/2000LCD
LCDonly)
only)
SoftwareCD QuickStartGuide ServiceGuide

4.ProductOverview
EN
FrontPanel:
LCDPanel:
LCDpanel
Inputvoltage
Loadlevelindicator,flashing
Outputvoltage indicatesoverload
Powerswitch
ACmodeindicator
Batterycapacityindicator,flashing
Batter
BackPanel:
VI450/650/850LCD VI1000LCD VI1500/2000LCD
Outputreceptacles
Outputreceptacles
Outputreceptacles
ACinput
ACinput
ACinput
Modemorphone
Circuitbreaker
Circuitbreaker
surgeprotection
Modemorphonesurge
Modemorphonesurge
USBport
protection
protection
Breaker
USBport
USBport
y
modeindicator indicateslowbatter
y

4.InstallationandInitialStartup
EN
Beforeinstallation,pleaseinspecttheunit.Besurethatnothingisdamaged.
I:Placement&StorageConditions
InstalltheUPSinaprotectedareathatisfreeofexcessivedustandhasadequateairflow.Please
placetheUPSawayfromotherunitsatleast20cmtoavoidinterference.DoNOToperatethe
UPSwherethetemperatureexceeds0‐40°C
andthehumidityisover0‐90%RH.
II:ConnecttoUtilityandCharge
PlugintheACinputcordtothewalloutlet.Forthebestresults,wesuggestchargingthebattery
atleast4hoursbeforeinitialuse.Theunitchargesitsbatterywhileconnectingtotheutility.
III:ConnecttheLoads
Pluginthe
loadstooutputreceptaclesontherearpaneloftheUPS.Simplyturnonthepower
switchofUPSunit,anddevicesconnectedtotheUPSwillbeprotectedbyUPSunit.
DonotattachapowerstriporsurgesuppressortotheUPS.
IV:ConnectModemorPhoneforSurgeProtection
Connectasinglemodemorphonelineintosurge‐
protected“IN”outletonthebackpanelofthe
UPSunit.Connectfrom“OUT”outlettothecomputerwithanotherphonelinecable.
V:Connec tUSBCable
TomonitortheUPSstatus,suchasunattendedUPSshutdownandstart‐up,byusingbundled
software,pleaseconnecttheUPSandPCwith
USBcableincluded.

NEVERconnectalaserprinterorscannertothe
UPSunit,becausein‐rushcurrentgeneratedby
EN
motor’sdevicesmaycausethedamageoftheunit.
VI:TurnOn/OfftheUnit
TurnontheUPSunitbypressingthepowerswitch.TurnofftheUPSunitbypressingagainthe
powerswitch.
6.AudiblealarmfromtheUPS
•
WhenUPSswitchesfromACmodetoBatteryModetobackuppowersupply:sounding
every10seconds
•
Whenbatteryislow:soundingeverysecond
•
WhenUPSisoverloaded:soundingevery0.5second
•
Whenbatteryisfaulty:soundingevery2seconds
•
Otherfault:Continuoussounding
7.SoftwareInstallationonyourPC
• Use the bundled CD and follow the on‐screen instructions to install the software
ViewPower.
• After the software is successfully installed, the communication with UPS has been
establishedandanorangeiconwillappearinthesystemtray.
• Double‐clicktheicontousethemonitor(as
above).
• YoucanscheduleUPSshutdown/start‐upandmonitorUPSstatusthroughPC.
• Detailinstructionspleaserefertothee‐manualinthesoftware.

8.Specifications
Model VI450LCD VI650LCD VI850LCD
EN
CAPACITY 450VA/240W 650VA/360W 850VA/480W
INPUT
Voltage 220~240VAC
VoltageRange 162~290VAC
FrequencyRange 50/60Hz±1Hz
OUTPUT
VoltageRegulation +/‐10%
TransferTime Typical2‐6ms,10msmax.
Waveform SimulatedSineWave
Protection Shortcircuitandoverloadprotection
BATTERY
Type&Number 12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1
ChargingTime 4‐6hoursrecoverto90%capacity
Protection Dischargeandoverchargeprotection
BackupTime(est.120W) 5min 10min 15min
PHYSICAL
LCDIndicator Input/outputvoltage,ACmode,Loadlevel,Batterycapacity
Dimension(DxWxH) 287mmx100mmx142mm
ENVIRONMENT
Humidity 0‐90%RH@0‐40°C(non‐condensing)
NoiseLevel Lessthan40dB
Model VI1000LCD VI1500LCD VI2000LCD
CAPACITY 1000VA/600W 1500VA/900W 2000VA/1200W
INPUT
Voltage 220/230/240VAC
VoltageRange 162~290VAC
FrequencyRange 50/60Hz(Autosensing)
OUTPUT
VoltageRegulation +/‐10%
FrequencyRange 50or60Hz+/‐1Hz
TransferTime Typical2‐6ms,10msmax.
Waveform SimulatedSineWave
BATTERY
Type&Number 12V/7Ahx2 12V/9Ahx2 12V/9Ahx2
ChargingTime 4‐6hoursrecoverto90%capacity
Protection Overload,dischargeandoverchargeprotection
BackupTime(est.240W) 11min 18min 20min
PHYSICAL
LCDIndicator Input/outputvoltage,ACmode,Loadlevel,Batterycapacity
Dimension(DxWxH) 350x146x160mm 397mmx146mmx205mm
ENVIRONMENT
Humidity 0‐90%RH@0‐40°C(non‐condensing)
NoiseLevel Lessthan40dB