IMPORTANTSAFETYINSTRUCTIONS

EN

SAVETHESEINSTRUCTIONSThismanualcontainsimportantinstructionsformodels

PowerWalkerVI450/650/850/1000/1500/2000LCDthatshouldbefollowedduringinstallation

andmaintenanceoftheUPSandbatteries.

ThisproductisspeciallydesignedforPCsanditisnotrecommendedforuseinanylife

supportingsystemandotherspecificimportantequipment.

Thisequipmentcanbeoperatedbyanyindividualwithnoprevioustraining.

DonotplughouseholdappliancessuchashairdryerstoUPSreceptacles.

Thisunitintendedforinstallationinacontrolledenvironment(temperaturecontrolled,

indoorareafreeofconductivecontaminants).AvoidinstallingtheUPSinlocationswhere

thereisstandingorrunningwater,orexcessivehumidity.

Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer

servicing

toqualifiedservicepersonnel.

Theutilitypoweroutletshallbeneartheequipmentandeasilyaccessible.ToisolateUPS

fromACinput,removetheplugfromtheutilitypoweroutlet.

IfUPSistobestoredforalongtime, it isrecommendedto recharge the batteries(by

connecting

theutilitypowertoUPS,switch“ON”),onceamonthfor24hourstoavoida

fullbatterydischarge.

PleasedonotusetheUPSinexcessoftheratedloadcapacity.

The UPS contains one/two largecapacity batteries. So the shell shall not be opened,

otherwise such

dangers as electric shock will be caused. If any internal overhaul or

replacementofthebatteryisrequired,pleasecontactthedistributor.

TheinternalshortcircuitingoftheUPSwillleadtodangerssuchaselectricshockorfire,

therefore,nowatercontainers(suchasawaterglass)shallbe

placedonthetopofthe

UPSsoastoavoidsuchdangersaselectricshock.

Donotdisposeofbatteryorbatteriesinafire.Thebatterymayexplode.

Donotopenormutilatethebatteryorbatteries.Releasedelectrolyteisharmfultothe

skinandeyes.

Itmaybetoxic.

IconΦontheratinglabelstandsforphasesymbol.

A battery can present a risk of electrical shock and high short circuit current. The

followingprecautionsshouldbeobservedwhenworkingonbatteries:

Removewatches,rings,orothermetalobjectsfromthehand.

Usetoolswithinsulatedhandles.

Servicingofbatteriesshouldbeperformedorsupervisedbypersonnelknowledgeableof

batteries and the required precautions.Keep unauthorized personnel away from

EN

batteries.

Whenreplacingbatteries,replacewiththesametypeandnumberofthesealedleadacid

batteries.

Themaximumambienttemperatureratingis40°

C.

This pluggable type A equipment with battery already installed by the supplier is

operatorinstallableandmaybeoperatedbylaymen.

Duringtheinstallationofthisequipmentitshouldbeassuredthatthesumoftheleakage

currentsoftheUPSandtheconnectedloadsdoesnotexceed

3.5mA.

Attention, hazardous through electric shock. Also with disconnection of this unit from

the mains, hazardous voltage stillmay beaccessible through supply from battery.The

battery supply should be therefore disconnected in the plus and minus pole of the

batterywhenmaintenanceorserviceworkinsidetheUPS

isnecessary.

ThemainssocketoutletthatsuppliestheUPSshallbeinstalledneartheUPSandshallbe

easilyaccessible.

In case smoke is found coming out from the device, please cut off the power supply

quicklyandcontactthedistributor.

Donotkeeporusethis

productinanyofthefollowingenvironments:

o Anyareawithcombustiblegas,corrosivesubstanceorheavydust.

o Anyarea with extraordinarily high orlow temperature (above40˚C or below

0˚C)andhumidityofmorethan90%.

o Anyareaexposedtodirectsunshineornearany

heatingapparatus.

o Anyareawithseriousvibrations.

o Outdoor.

Intheeventthatthereisfireoccurringinthevicinity,pleaseusedrypowerextinguishers.

Theuseofliquidextinguishersmaygiverisetothedangerofelectricshock.

ThisproductcomplieswiththesafetyandenvironmentalregulationsinEU.

Ifthetimearisestothrowawayyourproduct,pleaserecycleallthecomponentspossible.Batteries

andrechargeablebatteriesarenottobedisposedinyourdomesticwaste!Pleaserecyclethemat

yourlocalrecyclingpoint.Togetherwecanhelptoprotecttheenvironment.

1.Introduction

EN

PowerWalker VI seriesis an intelligent and compact line interactiveUPS (UninterruptiblePower

Supply)which isdesignedto protect your personalcomputeror sensitive electronicequipments

fromallformsofpowerinterference,includingcompletepowerfailures.Itisequippedwithmany

featuresthatallowanyattachedequipmenttooperatelongerand

morereliability.

2.Greenconceptdesign

PowerWalker VI 450/650/850/1000/1500/2000 LCD series adopt switching mode charging which

createsavarietyofbenefits:

Increaseschargingefficiencytomorethan80%,moreenergysavingthantraditionalUPS

Thebatteryrequiresonly4hourstobe90%charged,reducing50%ofchargingtime

Reducesheatgenerationduring

batterycharging,providingalongerbatterylife

Increasesreliabilityandhelpstosavemoney

3.PackageContent s

Youshouldhavereceivedthefollowingitemsinsideofpackage:



UPSUnit USBCable IECCable

ACInputPowerCord

(forVI1000/1500/2000

(forVI1500/2000LCD

LCDonly)

only)

SoftwareCD QuickStartGuide ServiceGuide



4.ProductOverview

EN

FrontPanel:

LCDPanel:

LCDpanel

Inputvoltage

Loadlevelindicator,flashing

Outputvoltage indicatesoverload

Powerswitch

ACmodeindicator

Batterycapacityindicator,flashing

Batter

BackPanel:

VI450/650/850LCD VI1000LCD VI1500/2000LCD

Outputreceptacles

Outputreceptacles

Outputreceptacles

ACinput

ACinput

ACinput

Modemorphone

Circuitbreaker

Circuitbreaker

surgeprotection

Modemorphonesurge

Modemorphonesurge

USBport

protection

protection

Breaker

USBport

USBport

y

modeindicator indicateslowbatter

y

4.InstallationandInitialStartup

EN

Beforeinstallation,pleaseinspecttheunit.Besurethatnothingisdamaged.

I:Placement&StorageConditions

InstalltheUPSinaprotectedareathatisfreeofexcessivedustandhasadequateairflow.Please

placetheUPSawayfromotherunitsatleast20cmtoavoidinterference.DoNOToperatethe

UPSwherethetemperatureexceeds040°C

andthehumidityisover090%RH.

II:ConnecttoUtilityandCharge

PlugintheACinputcordtothewalloutlet.Forthebestresults,wesuggestchargingthebattery

atleast4hoursbeforeinitialuse.Theunitchargesitsbatterywhileconnectingtotheutility.

III:ConnecttheLoads

Pluginthe

loadstooutputreceptaclesontherearpaneloftheUPS.Simplyturnonthepower

switchofUPSunit,anddevicesconnectedtotheUPSwillbeprotectedbyUPSunit.

DonotattachapowerstriporsurgesuppressortotheUPS.

IV:ConnectModemorPhoneforSurgeProtection

Connectasinglemodemorphonelineintosurge

protected“IN”outletonthebackpanelofthe

UPSunit.Connectfrom“OUToutlettothecomputerwithanotherphonelinecable.

V:Connec tUSBCable

TomonitortheUPSstatus,suchasunattendedUPSshutdownandstartup,byusingbundled

software,pleaseconnecttheUPSandPCwith

USBcableincluded.

NEVERconnectalaserprinterorscannertothe

UPSunit,becauseinrushcurrentgeneratedby

EN

motorsdevicesmaycausethedamageoftheunit.

VI:TurnOn/OfftheUnit

TurnontheUPSunitbypressingthepowerswitch.TurnofftheUPSunitbypressingagainthe

powerswitch.

6.AudiblealarmfromtheUPS

WhenUPSswitchesfromACmodetoBatteryModetobackuppowersupply:sounding

every10seconds

Whenbatteryislow:soundingeverysecond

WhenUPSisoverloaded:soundingevery0.5second

Whenbatteryisfaulty:soundingevery2seconds

Otherfault:Continuoussounding

7.SoftwareInstallationonyourPC

Use the bundled CD and follow the onscreen instructions to install the software

ViewPower.

After the software is successfully installed, the communication with UPS has been

establishedandanorangeiconwillappearinthesystemtray.

Doubleclicktheicontousethemonitor(as

above).

YoucanscheduleUPSshutdown/startupandmonitorUPSstatusthroughPC.

Detailinstructionspleaserefertotheemanualinthesoftware.

8.Specifications

Model VI450LCD VI650LCD VI850LCD

EN

CAPACITY 450VA/240W 650VA/360W 850VA/480W

INPUT

Voltage 220~240VAC

VoltageRange 162~290VAC

FrequencyRange 50/60Hz±1Hz

OUTPUT

VoltageRegulation +/10%

TransferTime Typical26ms,10msmax.

Waveform SimulatedSineWave

Protection Shortcircuitandoverloadprotection

BATTERY

Type&Number 12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1

ChargingTime 46hoursrecoverto90%capacity

Protection Dischargeandoverchargeprotection

BackupTime(est.120W) 5min 10min 15min

PHYSICAL

LCDIndicator Input/outputvoltage,ACmode,Loadlevel,Batterycapacity

Dimension(DxWxH) 287mmx100mmx142mm

ENVIRONMENT

Humidity 090%RH@040°C(noncondensing)

NoiseLevel Lessthan40dB

Model VI1000LCD VI1500LCD VI2000LCD

CAPACITY 1000VA/600W 1500VA/900W 2000VA/1200W

INPUT

Voltage 220/230/240VAC

VoltageRange 162~290VAC

FrequencyRange 50/60Hz(Autosensing)

OUTPUT

VoltageRegulation +/10%

FrequencyRange 50or60Hz+/1Hz

TransferTime Typical26ms,10msmax.

Waveform SimulatedSineWave

BATTERY

Type&Number 12V/7Ahx2 12V/9Ahx2 12V/9Ahx2

ChargingTime 46hoursrecoverto90%capacity

Protection Overload,dischargeandoverchargeprotection

BackupTime(est.240W) 11min 18min 20min

PHYSICAL

LCDIndicator Input/outputvoltage,ACmode,Loadlevel,Batterycapacity

Dimension(DxWxH) 350x146x160mm 397mmx146mmx205mm

ENVIRONMENT

Humidity 090%RH@040°C(noncondensing)

NoiseLevel Lessthan40dB