IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI
400 SE/600 SE/800 SE/1000 SE/1400 SE/2000 SE that should be followed during installation and
maintenance of the UPS and batteries.
• This product is specially designed for PCs and it is not recommended for use in any life-supporting
system and other specific important equipment.
• This equipment can be operated by any individual with no previous training.
• Do not plug household appliances such as hair dryers to UPS receptacles.
• This unit intended for installation in a controlled environment (temperature controlled, indoor area
free of conductive contaminants). Avoid installing the UPS in locations where there is standing or
running water, or excessive humidity.
• Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.
• The utility power outlet shall be near the equipment and easily accessible. To isolate UPS from AC
input, remove the plug from the utility power outlet.
• If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the
utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge.
• Please do not use the UPS in excess of the rated load capacity.
• The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such
dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is
required, please contact the distributor.
• The internal short circuiting of the UPS will lead to dangers such as electric shock or fire, therefore,
no water containers (such as a water glass) shall be placed on the top of the UPS so as to avoid such
dangers as electric shock.
• Do not dispose of battery or batteries in a fire. The battery may explode.
• Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
• Icon Φ on the rating label stands for phase symbol.
• A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries :
• Remove watches, rings, or other metal objects from the hand.
• Use tools with insulated handles.
EN

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and
the required precautions. Keep unauthorized personnel away from batteries.
• When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.
• The maximum ambient temperature rating is 40°C.
• This pluggable type A equipment with battery already installed by the supplier is operator installable
and may be operated by laymen.
• During the installation of this equipment it should be assured that the sum of the leakage currents
of the UPS and the connected loads does not exceed 3.5mA.
• Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole of the battery when maintenance or service work
inside the UPS is necessary.
• The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily
accessible.
• In case smoke is found coming out from the device, please cut off the power supply quickly and
contact the distributor.
• Do not keep or use this product in any of the following environments:
o Any area with combustible gas, corrosive substance or heavy dust.
o Any area with extraordinarily high or low temperature (above 40˚C or below 0˚C) and
humidity of more than 90%.
o Any area exposed to direct sunshine or near any heating apparatus.
o Any area with serious vibrations.
o Outdoor.
• In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use of
liquid extinguishers may give rise to the danger of electric shock.
This product complies with the safety and environmental regulations in EU.
If the time arises to throw away your product, please recycle all the components possible. Batteries and
rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at your local
recycling point. Together we can help to protect the environment.
EN

1. Introduction
PowerWalker VI series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which
is designed to protect your personal computer or sensitive electronic equipments from all forms of power
interference, including complete power failures. It is equipped with many features that allow any attached
equipment to operate longer and more reliability.
2. Description of Features
• Easy to use and install utilized microprocessor control to maximize the reliability and efficiency
Equipped with built-in boost and buck AVR function
• Cold start function
• Battery power energy saving and overload protection
• Provides advanced telephone/fax or modem surge suppression protection
3. Package Contents
You should have received the following items inside of package:
UPS Unit USB Cable AC Input Power Cord
(for VI 1000SE/ 1400SE/
2000SE only)
Software CD Quick Start Guide Service Guide
EN

4. Product Overview
Front Panel:
VI 400SE/600SE/800SE VI 1000SE/1400SE/2000SE
Power ON/OFF
AC input (green)
Power ON/OFF
AC input (green)
Faulty LED (red)
Load level / battery capacity (green LED)
Back Panel:
VI 400SE/600SE/800SE VI 1000SE/1400SE/2000SE
EN