Fenix Therm 105: Troubleshooting
Troubleshooting: Fenix Therm 105

Troubleshooting
Important The underoor heating
system is an electrical power installa-
tion and any faults must therefore be
remedied by a qualied electrician.
EN
Fault indication
In the event of damage or breakdown
of the oor sensor the thermostat
switches o and the light starts to ash
alternately green and red.
If the floor sensor should be defective
it can be replaced, provided that it is
installed in a spiral hose laid in the oor
as per instructions.
Test values for oor sensor
The following values apply when
the oor sensor’s measurements are
checked.
Temperature Resistance
o
10
C 18,0 kΩ
o
15
C 14,7 kΩ
o
20
C 12,1 kΩ
o
25
C 10,0 kΩ
o
30
C 8,3 kΩ
31
Table of contents
- Fenix-Therm 105
- Obsah balení
- Instalace
- Začínáme
- Popis funkce
- Řešení problémů
- Technické údaje
- Příslušenství
- Introduction
- In the pack
- Getting started
- Troubleshooting
- Technical specications
- Accessories
- Einführung
- Paketinhalt
- Erste Schritte
- Fehlerbehebung
- Technische Spezikationen
- Zubehör
- Termostaten
- I forpakningen
- Installere Termostaten
- Komme i gang
- Slik fungerer Termostaten
- Feilsøking
- Tekniske data
- Tilbehør
- Введение
- В упаковке
- Установка Fenix-Therm
- Начало работы
- Как работает термостат
- Поиск и устранение неисправностей
- Технические характеристики
- Дополнительные принадлежности
Top 10 manuals
100.00
NZXT HALE90 1000W99.99
Samsung SM-R38099.97
AEG BSB 18C99.97
Dell 2700W99.97
Smeg KSEC70X99.96
Beurer HDE 4099.96
Pyramida KH 50 v.299.96
MSI CSM-H81M-P3299.96
AEG HR 562799.95
Melissa 640-048