Pyramida CXW-KH 60: CXW-KH 50 Household cooking hoods CXW-KH 60 MAINTENANCE MANUAL EN

CXW-KH 50 Household cooking hoods CXW-KH 60 MAINTENANCE MANUAL EN: Pyramida CXW-KH 60

CXW-KH 50

Household cooking hoods

CXW-KH 60

MAINTENANCE MANUAL EN

DESCRIPTION

Thank you for purchasing Pyramida cooking hood!

Pyramida cooking hoods are reliable and easy-to-work. To guarantee long and nonfailure operation, read the following

manual.

This maintenance manual is combined with technical description and includes data concerning setting and installation,

operating rules and product maintenance regulations.

In connection with the fact that the extractor fan device is upgraded all the time, insignificant discrepancies

between the structure of Your extractor fan and maintenance manual are possible, that do not influence

technical characteristics, maintenance safety and consumer properties.

The product is designed for exhaust ventilation of the

The cooking hood mounted with air duct is related to the

household accommodation spaces heated during the winter

IP23 class devices in the type of protection against access to

time. Commercial operation and use of the product are not

the dangerous parts and water intrusion.

provided for services enterprises, public health services, etc.

The climatic modification of the product is UHL4.2

Never use cooking hood outdoors!

according to GOST 15150-69. It is permissible to run the

Given model can be used for inside filtration (air recirculation

product at temperature of ambient air in limits from +1°C to

inside the premise at installed charcoal filters).

+45°C. The product must be stored in ventilated location in

The product is equipped with illuminating lamps. It is

the manufacturer’s pack at temperature from 0°C to +50°C

supplied with network cable with mains plug and designed

and with related air humidity of not more than 90%.

for connection to the single-phase AC network with voltage of

220…240V and with frequency of 50Hz.

The equipment is adequate to the requirements of

The product is related to the І class devices according to the

Technical regulations for use of some dangerous substances

DSTU 3135.26-98 (GOST 30345.26-98) in type of protection

in electrical and electronic equipment.

against electric shock and supplied with grounding wire

ingressed into the power cable.

Product life cycle: 5 years.

EN

26

EXTRACTOR FAN STRUCTURE

Construction of the cooking hood

Following is included into delivery set:

1 – Top decorative casing

Cooking hood – 1 pc.

2 – Lower decorative casing

Mounting bar – 1 pc.

3 – Case of the cooking hood with control panel

Air duct adapter – 1 pc.

4 – Motor

Installation kit – 1 pc.

5 – Fat filters

User manual – 1 pc.

Warranty certificate – 1 pc.

Box packaging – 1 pc.

Technical features:

Model

CXW-KH 50 CXW-KH 60

Network voltage, V 220…240 220…240

Frequency, Hz 50 50

Rated current, А 0,65 0,65

Control Mechanical push-button control

Number of motors, pcs. 1 1

Motor power, W 80 80

Overall power, W 160 160

Performance, cubic m./hour 600 700

Noise level, dB 58 58

Amount of fat filters (five-layer

2 2

aluminum), pcs.

Amount of glow lamps (40W), pcs. 2 2

Air duct diameter, mm 120 120

Dimensions without air duct (WxDxH), mm 500х500х940 600х500х940

Weight, kg 9,5 10,8

White / Black / Brown /

Colour

Ivory / Stainless steel

27

OPERATION SAFETY REQUIREMENTS

Single-phase network, to which the

they are under control or have been instructed by the person

product is connected, has to correspond

responsible for their safety. Children have to be under control

to the acting roles. Connection has to

of adults for avoiding of games with the device.

be done via automatic circuit-breaker, built-in to the fixed

wiring on your electric service panel. All actions related to

Pumped air cannot contain dust and other solid impurities,

the connection, adjustment, maintenance and repair of the

and also sticky substances or fibrous materials. It is forbidden

device, and retubing are to be done without line voltage! For

to use the product with present inflammable substances and

this you need to switch off the electric switch on your panel or

their fume, such as spirit, benzine, insecticides, etc.

drag out the plug from the socket. Do not pull the plug wire!

Do not pinch or strain network cable.

Do not shut or bar suction and discharge port of the device,

not to prevent optimal passing of the air. Don’t reduce

Extenders and adapters use is forbidden. Manufacturer

diameter of the air duct to less than 120mm.

of extractor fan does not respond for breakdowns or

inflammations arisen as a result of T-bends or extenders

Do not sit down on the product and don’t put any objects

use. To replace damaged network cable call specialist from

on it.

a service center.

Under the extractor fan one cannot cook such dishes

Before installation it is necessary to be sure that there are

as flambé (dishes that are poured with alcohol and set

no visible damages of the propeller, extractor fan case, and

on fire). Watch that during cooking there is no oil ignition.

also there are no foreign objects in the flowing part of the

Remember that repeated use of oil increases probability of

case, that can damage propeller blades. If you doubt that the

its autoignition.

fan is intact and complete, call the seller immediately.

Do not leave the fan in use unattended for a long time.

It is forbidden to misuse the device, modify it or update.

After the fan has been in use for a long time don’t touch

the backlights they are hot. While replacement of lamps it

Product is not intended to be used by children and persons

is necessary to disconnect the device from electric network.

with reduced physical, sensory or mental abilities or if they

don’t have any experience in using extractor fans, unless

Don’t touch the fan surface with wet hands.

EN

28

Regularly clean fat filters. Don’t remove fat filters while the

for the safety of children who can play with unused or thrown

fan is running.

out devices).

If non-standard situation of failure arises disconnect the

After product life cycle expiry the device is liable to

device from the network and call the service center, its address

particular utilization. Do not throw the device out

is in the warranty certificate. If you have decided that the

together with ungraded domestic waste.

device is non-serviceable, make it unsuitable for exploitation:

disconnect it from the electric network, cut power cable,

If present maintenance is disregarded, manufacturer is not

remove potentially dangerous parts (it is especially important

responsible for possible malfunctions.

ABSOLUTELY FORBIDDEN!

Do not lead extractor fan air duct to stove and gas appliance flues, intended for water and room heating, to air channels,

intended for other devices.

Do not check the draught of the running fan with torch or open flame – this can lead to fire.

Do not set fire to burners of gas cooker without dishware (e.g. for room heating). Use of open flame can be dangerous

and damage plastic parts of the extractor fan or cause ignition.

Change of fan structure and other interferences into the device by persons not authorized to warranty repair by the

manufacturer, is forbidden

29

ASSEMBLY SAFETY REGUIREMENTS

Before you start to assemble the

product it is necessary to de-energize

the power network!

Minimal distance between cooking

surface and lower plane of the

extractor fan must be:

- for electric fryers not less than

600 mm;

≥ 650 мм

- for gas fryers not less than

650 mm.

If you use air duct consisting of

several parts, each next part must be

placed outside relative to previous.

If there is a stove, gas boiler or geyser in the room, it

To guarantee safe operation of the fan in closed space, there

is necessary to take into account that while running the

should be additional air intake from outside (open ventlight in

extractor fan takes air from the room which is necessary for

another room, open door to the kitchen or specially equipped

burning. This also concerns to the room with airtight windows

forced ventilation).

and doors.

If the fan is staffed with electric cable without the plug,

it is necessary to de-energize the network according to the

following scheme:

BROWN wire = L («live»)

BLUE wire = N («neutral»)

GREEN and YELLOW wire = Е («earth»)

EN

30

CONTROL PANEL

Do not forget to turn on cooking hood while starting to

1. Turn on or off the lightning.

use the kitchen stove or cooktop. It is necessary for normal

2. Turns off the fan.

ventilation of the kitchen.

3. Turns off the low speed of the

For full ventilation it is necessary to turn off cooking hood

fan.

4. Turns on low speed of the

after duration of the period of 15 minutes after cooking.

fan.

The cooking hood is equipped with front control panel

5. Turns on high speed of the

constituting the row of buttons. The speeds are switched by

1 2 43 5

fan.

the means of the buttons «•», «••», «•••».

Operation of the cooking hood is enough at low speeds at

simultaneous work of all fore burners.

reheating of the food. Average speed is used for standard

Switching of the speed buttons can be performed in any

conditions of cooking (boiling and frying).

order. Use the button “0” for fan turn off.

The high speed is designed for removal of the large amount

of vapor, smoke and mixed kitchen odors from the premise, at

RECIRCULATION

The following actions must be done for work of the cooking

hood in mode of an air recirculation:

- Do not connect cooking hood to the air duct (it is allowed

not to install an air duct adapter );

- install casing of the air duct in such a way as jalousies on

it not to be overlapped;

- Install additional charcoal filters into the cooking hood

(2 pcs.).

The charcoal filters are not included into the delivery set of

the cooking hood and should be purchased separately.

The charcoal filters are not subject to cleaning and should

be replaced with new after 3-4 months.

31

INSTALLATION OF EXTRACTOR FAN TO THE WALL

1. Mount the back surface

of the cooking hood to

Mounting

the wall by the means of

points

the screws with dowels

from the installation kit.

2. Install the adapter of air

duct onto the cooking

hood by the means of

screws with use of seal

from installation kit.

3. Connect the air duct

to the adapter of the

Mounting points

cooking hood. Take out

another end of an air duct

to the air-shaft. Ensure

that chinks are absent in

the connections.

4. Install casings of an air

duct and fix them with

screws from installation

kit.

EN

32

PRODUCT MAINTENANCE

The works on maintenance should be performed on

- Regularly remove all food debris and fat from the lower

cooking hood with the purpose of maximal performance and

surface of the cooking hood and from aluminum fat

effectiveness of its operation during the life time.

filters. An excessive fatness can lead to fire!

- Wipe the external surfaces of the cooking hood with the

The cooking hood should be discon-

humid, good squeezed flannel tissue.

nected from the power network at

- Use special fluids creating the protective film for handling

works connected to the maintenance

the surfaces made of stainless steel.

on cooking hood.

- Do not use the abrasive agents and solvents.

- Verify the conditions of the air duct of cooking hood and

Regularly perform following actions at maintenance:

ventilation channel, clean them at necessity!

BACKLIGHTS REPLACEMENT

In the extractor fan lighting lamps of type Е14 are used,

- press the filter lock and take off the fat filter;

their power is not more that 40 W. Replacement of lamps is

- Unscrew an old lamp from the holder and screw the new

made in the following order:

one;

- Make sure that cooking hood is disconnected from power

- press the filter lock and install the fat filter into the cooking

network before lamps replacement; wait until lamps will

hood.

cool down.

E14 40Вт

33

FILTER CLEANING

Extractor fan is equipped with removable protective fat

Manual cleaning is carried out in the following order:

filters. Filters guarantee absorption of suspended solids,

- remove the filter, having pressed the filter lock beforehand;

that’s why they can become dirty depending on frequency of

- wash the filter with cleaning agent or suds with the help

fan use.

of sponge or dauber;

- thoroughly wash the filter with warm water;

To guarantee maximum capacity and efficiency of fan

- wait until the filter is absolutely dry;

work, it is necessary to regularly clean fat filters from

- set the filter into the extractor fan, having pressed the

contaminations.

filter lock beforehand.

In case of cleaning with a dishwashing machine make sure

Cleaning is carried out each 5-6 weeks by hand with suds

that the cleaning agents you use with your machine do not

without strong mechanical effect or in dishwashing machine.

contain deleterious substances that may damage the surface

of aluminum filter details. In the dishwashing machine, place

filters vertically to avoid food remains getting in. Before

Cleaning of fat filters periodicity

installation of the filter into the fan after washing in the

increase complicates air absorption

dishwashing machine make sure that the filter is dry. In case

by the fan. This leads to engine load

of failure to comply present roles the filter may be damaged!

increment and may influence extractor fan life time.

EN

34

WARRANTY

The product obeys the following European norms:

At purchasing of the product press for warranty certificate

directive of EMC 89/336/EEC, 92/31/EEC,

correct filling in.

93/68/ЕЕС and IEC 60335-2-31.

Warranty service is not performed in the following cases:

Manufacturer guarantees normal operation of the product

- by failure to comply with rules stated in the manual;

during 24 months since the day of sale through retail

- by reduction of the air duct diameter to less than

distribution network on condition that transport, storing,

120 mm;

mounting and exploitation regulations, stated in present

- by presence of obstacles to free air circulation from the

manual, are fulfilled. If your extractor fan does not work in

extractor fan to air channel exit;

a proper way, call service center, maintaining TM Pyramida

- by incorrect assembly, in case of opening or wiring pod, by

products, and do not forget to report the following information:

replacement of the network cable;

- number of warranty policy;

- by supply network contradiction to the parameters set by

- product model;

the manufacturer;

- serial number, stated on information label of the fan or in

- by mechanical or other damages of the device as a result

the warranty certificate;

of rough handling;

- failure description.

- by installation of the fan lower that in 60 cm from burners

Claims won’t be considered without warranty certificate

and heaters.

with the date of sale and stamp of commercial organization.

35