Stiebel Eltron PSH 100 Trend: OPERATION

OPERATION: Stiebel Eltron PSH 100 Trend

Special information

- Install a type-tested safety valve in the cold water

OPERATION

supply line. For this bear in mind that, depending

on the static pressure, you may also need a pres-

sure reducing valve.

1. General information

- Size the drain so that water can drain off unim-

The chapters "Operation" and "Special Information" are intended

peded when the safety valve is fully opened.

for both the user and qualified contractors.

- Fit the discharge pipe of the safety valve with

The chapter "Installation" is intended for qualified contractors.

a constant downward slope and in a room free

from the risk of frost.

Note

Read these instructions carefully before using the appli-

- The safety valve discharge aperture must remain

ance and retain them for future reference.

open to the atmosphere.

Pass on the instructions to a new user if required.

1.1 Safety instructions

1.1.1 Structure of safety instructions

KEYWORD Type of risk

!

Here, possible consequences are listed that may result

from failure to observe the safety instructions.

Steps to prevent the risk are listed.

1.1.2 Symbols, type of risk

Symbol Type of risk

Injury

!

Electrocution

Burns

(burns, scalding)

1.1.3 Keywords

KEYWORD Meaning

DANGER Failure to observe this information will result in serious

injury or death.

WARNING Failure to observe this information may result in serious

injury or death.

CAUTION Failure to observe this information may result in non-seri-

ous or minor injury.

16 | PSH Trend www.stiebel-eltron.com

OPERATION

Safety

1.2 Other symbols in this documentation

2.2 General safety instructions

Note

WARNING Burns

General information is identified by the symbol shown

During operation, the tap and safety valve can reach

on the left.

temperatures in excess of 60°C.

Read these texts carefully.

There is a risk of scalding at outlet temperatures in ex-

cess of 43°C.

Symbol Meaning

WARNING Injury

Material losses

!

The appliance may be used by children aged 8 and up and

!

(appliance and consequential losses, environmental pol-

English

persons with reduced physical, sensory or mental capa-

lution)

bilities or a lack of experience and know-how provided

Appliance disposal

that they are supervised or they have been instructed

on how to use the appliance safely and have understood

the resulting risks. Children must never play with the

This symbol indicates that you have to do something. The ac-

appliance. Children must never clean the appliance or

tion you need to take is described step by step.

perform user maintenance unless they are supervised.

1.3 Units of measurement

Material losses

!

The user should protect the water lines and the safety

valve from frost.

Note

All measurements are given in mm unless stated oth-

erwise.

Note

The appliance is under pressure. During the heat-up

process, expansion water will drip from the safety valve.

If water continues to drip when heating is complet-

2. Safety

ed, please inform your qualified contractor.

2.1 Intended use

The appliance is intended for heating domestic hot water and can

2.3 CE designation

supply one or more draw-off points.

The CE designation shows that the appliance meets all essential

This appliance is intended for domestic use. It can be used safely

requirements according to the:

by untrained persons. The appliance can also be used in a non-do-

- Electromagnetic Compatibility Directive

mestic environment, e.g. in a small business, as long as it is used

- Low Voltage Directive

in the same way.

Any other use beyond that described shall be deemed inappro-

2.4 Test symbols

priate. Using the appliance for heating fluids other than water or

See type plate on the appliance.

water supplemented with chemicals, such as brine, is also deemed

inappropriate.

3. Appliance description

Observation of these instructions and of instructions for any ac-

cessories used is also part of the correct use of this appliance.

The closed (pressure-tested) appliance heats DHW electrically.

You can adjust the temperature using the temperature selector.

Subject to the power supply, the water is heated automatically to

the required temperature.

The internal steel cylinder is coated with special "Co Pro" enamel

and is equipped with a protective anode. The anode protects the

internal cylinder from corrosion.

Frost protection

The appliance is also protected against frost by the temperature

setting "*", provided that the power supply is guaranteed. The

appliance switches on in good time and heats the water. The ap-

pliance does not protect the water supply lines and the safety

valve from frost.

www.stiebel-eltron.com PSH Trend | 17

OPERATION

Settings

4. Settings

5. Cleaning, care and maintenance

Have the electrical safety of the appliance and the function of

The temperature can be freely adjusted.

the safety valve regularly checked by a qualified contractor.

Have the protective anode initially checked by a qualified

contractor after the first year. The qualified contractor will

then determine the intervals at which it must be checked

thereafter.

Never use abrasive or corrosive cleaning agents. A damp

cloth is sufficient for cleaning the appliance.

Scaling

Almost every type of water will deposit lime at high temper-

atures. This settles inside the appliance and affects both the

performance and service life. The heating elements must

therefore be descaled from time to time. A qualified contrac-

max

tor who knows the local water quality will tell you when the

next service is due.

1

Check the taps/valves regularly. You can remove limescale

2

D0000037146

deposits at the spouts using commercially available descaling

1 ON/OFF indicator

agents.

2 Temperature selector

Regularly activate the safety valve to prevent it from becom-

* Frost protection

ing blocked e.g. by limescale deposits.

E Recommended energy saving position, low scaling, 60°C

Max Maximum temperature setting, 75°C

6. Troubleshooting

Depending upon the system, the actual temperatures may vary

Problem Cause Remedy

from the set value.

The water does not heat

There is no power.

Check the fuses/MCBs in

up and the ON/OFF indi-

your fuse box.

ON/OFF indicator

cator does not illuminate.

The water does not heat

The temperature is set

Select a higher temper-

The ON/OFF indicator illuminates when water is being heated.

up sufficiently and the

too low.

ature.

ON/OFF indicator illumi-

nates.

4.1 Holiday and absence

The appliance heats,

Wait until the ON/OFF

If the appliance is not to be used for a few days, set the tem-

for example, after large

indicator goes out.

perature selector to a position between the frost protection

amounts of DHW have

been drawn.

and energy saving settings.

The flow rate is low.

The aerator in the tap or

Clean and/or descale the

If the appliance is not to be used for a longer period, set it to

shower head is scaled up

aerator or shower head.

frost protection to conserve energy. If there is no risk of frost

or contaminated.

you may disconnect the appliance from the power supply.

For reasons of hygiene, heat up the content of the water

If you cannot remedy the fault, notify your qualified contractor. To

heater once to above 60°C before initial use.

facilitate and speed up your enquiry, please provide the numbers

from the type plate (000000 and 0000-000000):

E-NO.: 000000

F-NO.: 0000-000000



18 | PSH Trend www.stiebel-eltron.com