Pyramida KH 50 v.2: ASSEMBLY SAFETY REGUIREMENTS

ASSEMBLY SAFETY REGUIREMENTS: Pyramida KH 50 v.2

CONTROL PANEL

1. Turns off the fan.

Do not forget to turn on cooking hood while starting to

2. Turns off the low speed of the

use the kitchen stove or cooktop. It is necessary for normal

fan.

ventilation of the kitchen.

3. Turns on low speed of the

fan.

4. Turns on high speed of the

For full ventilation it is necessary to turn off cooking hood

fan.

after duration of the period of 15 minutes after cooking.

5. Turn on or off the lightning.

1 2 43 5

The cooking hood is equipped with front control panel

constituting the row of buttons. The speeds are switched by

The high speed is designed for removal of the large amount

the means of the buttons «•», «••», «•••».

of vapor, smoke and mixed kitchen odors from the premise, at

simultaneous work of all fore burners.

Operation of the cooking hood is enough at low speeds at

reheating of the food. Average speed is used for standard

Switching of the speed buttons can be performed in any

conditions of cooking (boiling and frying).

order. Use the button “0” for fan turn off.

RECIRCULATION

The following actions must be done for work of the cooking

hood in mode of an air recirculation:

- Do not connect cooking hood to the air duct (it is allowed

not to install an air duct adapter );

- install casing of the air duct in such a way as jalousies on

it not to be overlapped;

- Install additional charcoal filters into the cooking hood

(2 pcs.).

The charcoal filters are not included into the delivery set of

the cooking hood and should be purchased separately.

The charcoal filters are not subject to cleaning and should

be replaced with new after 3-4 months.

31

ASSEMBLY SAFETY REGUIREMENTS

Before you start to assemble the

product it is necessary to de-energize

the power network!

Minimal distance between cooking

surface and lower plane of the

extractor fan must be:

- for electric fryers not less than

600 mm;

≥ 650 мм

- for gas fryers not less than

650 mm.

Providing the necessary clearance between the door spaceand

the threshold for the free passage of the supply air

If you use air duct consisting of

another room, open door to the kitchen or specially equipped

several parts, each next part must be

forced ventilation).

placed outside relative to previous.

If there is a stove, gas boiler or geyser in the room, it

To guarantee safe operation of the fan in closed space, there

is necessary to take into account that while running the

should be additional air intake from outside (open ventlight in

extractor fan takes air from the room which is necessary for

burning. This also concerns to the room with airtight windows

and doors.

If the fan is staffed with electric cable without the plug,

it is necessary to de-energize the network according to the

following scheme:

BROWN wire = L («live»)

BLUE wire = N («neutral»)

Direct exhaust An example of ensuring the flowair

GREEN and YELLOW wire = Е («earth»)

EN

30