Before you start to assemble the

product it is necessary to de-energize

the power network!

Minimal distance between cooking

surface and lower plane of the

extractor fan must be:

- for electric fryers not less than

600 mm;

≥ 650 мм

- for gas fryers not less than

650 mm.

If you use air duct consisting of

several parts, each next part must be

placed outside relative to previous.

If there is a stove, gas boiler or geyser in the room, it

To guarantee safe operation of the fan in closed space, there

is necessary to take into account that while running the

should be additional air intake from outside (open ventlight in

extractor fan takes air from the room which is necessary for

another room, open door to the kitchen or specially equipped

burning. This also concerns to the room with airtight windows

forced ventilation).

and doors.

If the fan is staffed with electric cable without the plug,

it is necessary to de-energize the network according to the

following scheme:

BROWN wire = L («live»)

BLUE wire = N («neutral»)

GREEN and YELLOW wire = Е («earth»)